English
Language : 

HCPL-2730-000E Datasheet, PDF (11/13 Pages) AVAGO TECHNOLOGIES LIMITED – Dual Channel Low Input Current, High Gain Optocouplers
Package Characteristics
Device
Parameter
Symbol HCPL- Min. Typ.* Max. Units Test Conditions
Fig.
Input-Output Momentary
VISO
3750 V rms RH ≤50%,
Withstand Voltage** t = 1 min.,
      Option 020
2730 5000 TA = 25°C
2731
Resistance
RI-O
1012
Ω
(Input-Output)
VI-O = 500 VDC
RH ≤45%
Capacitance
(Input-Output)
CI-O 0.6 pF f = 1 MHz
Input-Input Insulation
II-I 0.005 µA
Leakage Current
RH ≤45%
VI-I = 500 VDC
Input-Input Insulation
Leakage Current
RI-I
1011
Ω
Capacitance
CI-I
(Input-Input)
2730
2731
0.03
pF
0730 0.25
0731
Note
4, 9
4, 10
4
11
5
5
5
*All Typical values at TA = 25°C unless otherwise noted.
**The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous
voltage rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your equip-
ment level safety specification or Avago Application Note 1074 entitled “Optocoupler Input-Output Endurance Voltage.”
Notes:
  1. Pin 5 should be the most negative voltage at the detector side.
  2. Each channel.
  3. DC CURRENT TRANSFER RATIO (CTR) is defined as the ratio of output collector current, IO, to the forward LED input current, IF, times 100%.
  4. Device considered a two-terminal device: pins 1, 2, 3, and 4 shorted together, and pins 5, 6, 7, and 8 shorted together.
  5. Measured between pins 1 and 2 shorted together, and pins 3 and 4 shorted together.
  6. Common mode transient immunity in a Logic High level is the maximum tolerable (positive) dVCM/dt of the common mode pulse, VCM, to as-
sure that the output will remain in a Logic High state
(i.e., VO > 2.0 V). Common mode transient immunity in a Logic Low
level is the maximum tolerable (negative) dVCM/dt of the common mode pulse, VCM, to assure that the output will remain in a Logic Low state
(i.e., VO < 0.8 V).
  7. In applications where dV/dt may exceed 50,000 V/µs (such as static discharge) a series resistor, RCC, should be included to protect the detec-
tor IC from destructively high surge currents. The recommended value is RCC = 110 Ω.
  8. Use of a 0.1 µF bypass capacitor connected between pins 5 and 8 adjacent to the device is recommended.
  9. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage > 4500 V rms for 1 second (leakage
detection current limit,
II-O < 5 µA).
10. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage > 6000 V rms for 1 second (leakage
detection current limit,
II-O < 5 µA).
11. Measured between the LED anode and cathode shorted together and pins 5 through 8 shorted together.
12. Derate linearly above 65°C free-air temperature at a rate of 2.3 mW/°C for the SO-8 package.
11