English
Language : 

HCPL-2730-000E Datasheet, PDF (10/13 Pages) AVAGO TECHNOLOGIES LIMITED – Dual Channel Low Input Current, High Gain Optocouplers
Switching Specifications (AC)
Over recommended operating conditions (TA = 0°C to 70°C), VCC = 5 V, unless otherwise specified.
(See note 8.)
Parameter
Sym.
Device
HCPL- Min. Typ.* Max. Units    Test Conditions
Fig. Note
Propagation Delay
tPHL
Time to Logic
2731
25 100 µs TA = 25°C
0731
Low at Output 120
IF = 0.5 mA
Rl = 4.7 kΩ
6, 7, 2
8, 9
2730
5
20 TA = 25°C
2731
0730
0731
25 IF = 1.6 mA, Rl = 2.2 kΩ
0.5
2 TA = 25°C
3 IF = 12 mA, Rl = 270 Ω
Propagation Delay
tPLH
Time to Logic
2731
10
60
µs TA = 25°C
0731
7, 8, 2
9
High at Output
90 IF = 0.5 mA, Rl = 4.7 kΩ
2730
2731
10
35
TA = 25°C
0730
0731
50 IF = 1.6 mA, Rl = 2.2 kΩ
1
10 TA = 25°C
15 IF = 12 mA, Rl = 270 Ω
Common Mode
|CMH| 1000 10000 V/µs IF = 0 mA, TA = 25°C,
10 2, 6,
Transient Immunity Rl = 2.2 kΩ
7
at Logic High
Output
|VCM| = 10 Vp-p
Common Mode
|CML 1000 10000 V/µs
Transient Immunity
at Logic Low Level
Output
IF = 1.6 mA, TA = 25°C,
Rl = 2.2 kΩ
|VCM| = 10 Vp-p
*All typical values at TA = 25°C and VCC = 5 V, unless otherwise noted.
10