37.4 Wake-up time from sleep modes
Table 37-6. Device wake-up time from sleep modes with various system clock sources.
Symbol Parameter
Wake-up time from idle,
standby, and extended standby
mode
twakeup
Wake-up time from Power-save
and Power-down mode
Condition
External 2MHz clock
32.768kHz internal oscillator
2MHz internal oscillator
32MHz internal oscillator
External 2MHz clock
32.768kHz internal oscillator
2MHz internal oscillator
32MHz internal oscillator
Min.
Typ. (1)
2.0
120
2.0
0.2
4.5
320
9.0
5.0
Max. Units
µs
Note:
1. The wake-up time is the time from the wake-up request is given until the peripheral clock is available on pin, see Figure 37-2. All peripherals and modules start
execution from the first clock cycle, expect the CPU that is halted for four clock cycles before program execution starts.
Figure 37-2. Wake-up time definition.