English
Language : 

AT17F16_14 Datasheet, PDF (12/20 Pages) ATMEL Corporation – In-System Programmable (ISP) via 2-wire Bus
16.1 AC Characteristics When Cascading
AT17F16
Symbol
TCDF(3)
TOCK(2)
Description
CLK to Data Float Delay
CLK to CEO Delay
Commercial
Industrial
Commercial
Industrial
Min
Max
Units
50
ns
50
ns
50
ns
55
ns
TOCE(2)
CE to CEO Delay
Commercial
Industrial
35
ns
40
ns
TOOE(2)
RESET/OE to CEO Delay
Commercial
Industrial
35
ns
35
ns
FMAX
Notes:
Commercial
33
Maximum Input Clock Frequency
Industrial
33
1. AC test lead = 50 pF.
2. Float delays are measured with 5 pF AC loads. Transition is measured ± 200 mV from steady-state active levels.
MHz
MHz
17. Thermal Resistance Coefficients
Package Type
8CN4
Leadless Array Package (LAP)
20J
Plastic Leaded Chip Carrier (PLCC)
44A
Thin Plastic Quad Flat Package (TQFP)
Note: 1. Airflow = 0 ft/min.
θJC [° C/W]
θJA [° C/W](1)
θJC [° C/W]
θJA [° C/W](1)
θJC [° C/W]
θJA [° C/W](1)
AT17F16
–
–
–
–
17
62
12 AT17F16
3392F–CNFG–2/08