DIGITAL DATA CONVERSION (continued)
TMON:
Baseplate temperature monitoring is a read only data. It is ranged from -40ºC to 120ºC. The temperature of module can be
calculated by the equation below:
Receive Data (from module to PC):
Input Data: MCU Tmon (integer)
Output Data: Baseplate Temperature in °C (round to 1 decimal place)
Baseplate Temperature in °C = MCU Tmon × 500 − 273
1024
VOUT:
Output Voltage is a read only data. The output voltage can be calculated by the equation below:
Receive Data (from module to PC):
Input Data: MCU Vout (integer)
Output Data: Output Voltage in %Vonom (round to 1 decimal place)
Output
Voltage
in
%Vonom
=
MCU Vout
Vo _ REF
×100%
Module name
AIF120Y300-L/N-L/-NTL
AIF120F300-L/N-L/-NTL
AIF80A300-L/N-L/-NTL
AIF50B300-L/N-L/-NTL
AIF40C300-L/N-L/-NTL
AIF25H300-L/N-L/-NTL
AIF12W300-L/N-L/-NTL
Vo_REF
369
676
813
820
830
820
820