English
Language : 

AIF12W300 Datasheet, PDF (2/38 Pages) Astec America, Inc – DC-DC Converter Module
Technical Reference Notes
AIF12W300 DC-DC Series
Electrical Specifications
STANDARD TEST CONDITION on a single unit, unless otherwise indicated, electrical specifications apply over all
operating input voltage and temperature conditions.
Tamb
Vin
Enable
CLK IN
CLK OUT
CSHARE
Iout
AUX OUTPUT
-Sense
V ADJ
C MON
TEMP MON
C LIM ADJ
OVP ADJ
PG/ID
I/P Cap requirement
25°C
300 V± 2%
Open
Open
Open
Open
75% Io max ± 2%
Open
connect to –Vout
Open
Open
Open
Open
Open
Open
68µF/450V min.
ABSOLUTE MAXIMUM RATINGS
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress
ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the
operational sections of the IPS. Exposure to absolute maximum ratings for extended periods can adversely affect device
reliability.
Parameter
Input Voltage:
Continuous:
Transient (100ms)
Operating Baseplate Temperature
Start up Baseplate Temperature
Storage Temperature
Operating Humidity
I/O Isolation
Symbol
Min
Typ
Max
Unit
VI
250
-
VI, trans
-
Tc
-20
-
-
-40
-
TSTG
-55
-
-
15
-
-
2700
-
420
Vdc
500
Vdc
100
°C
100
°C
125
°C
95
%
-
Vdc
MODEL: AIF12W300 SERIES
JUNE 2006
SHEET 2 OF 37