English
Language : 

WB85 Datasheet, PDF (8/17 Pages) ASM GmbH – Analog Output
POSITAPE®
U2/PMU, U8/PMU and I1/PMU
Analog output, programmable
U2/PMU
Voltage output
0.5 ... 10 V
U8/PMU
Voltage output
0.5 ... 4.5 V
I1/PMU
Current output
4 ... 20 mA, 3 wire
Output signals
Excitation voltage
Excitation current
Output voltage
Output current
Measuring rate
Stability (temperature)
Protection
Operating temperature
EMC
Excitation voltage
Excitation current
Output voltage
Output current
Measuring rate
Stability (temperature)
Protection
Operating temperature
EMC
Excitation voltage
Excitation current
Load RL
Output current
Measuring rate
Stability (temperature)
Protection
Operating temperature
EMC
U2/PMU
U8/PMU
I1/PMU
10 ... 36 V DC
typ. 20 mA at 24 V DC, typ. 38 mA at 12 V DC
max. 60 mA
0,5 ... 10 V DC
2 mA max.
1 kHz standard
±50 x 10-6/°C f.s. (typical)
Reverse polarity, short circuit
-40 ... +85 °C
EN 61326-1:2013
10 ... 36 V DC
typ. 17 mA at 24 V DC, typ. 32 mA at 12 V DC
max. 60 mA
0,5 ... 4,5 V DC
2 mA max.
1 kHz standard
±50 x 10-6/°C f.s. (typical)
Reverse polarity, short circuit
-40 ... +85 °C
EN 61326-1:2013
10 ... 36 V DC
typ. 36 mA at 24 V DC , typ. 70 mA at 12 V DC
max. 100 mA
500 Ω max.
4 ... 20 mA
1 kHz standard
±50 x 10-6/°C f.s. (typical)
Reverse polarity, short circuit
-40 ... +85 °C
EN 61326-1:2013
Excitation +
Signal +
GND
SPAN/ZERO
)
Signal wiring/
connection
Signal
Excitation +
Signal
Connector
pin
1
2
Cable wire
color
brown
white
View to sensor
connector
GND
3
blue
Do not connect!
4
black
SPAN/ZERO
5
grey
Option -PMU
Programming of the start and end value by the customer
Teach-In of start and end value for the options U2/PMU, I1/PMU, U8/PMU is provided by a binary signal SPAN/ZERO. At
the start position connect signal SPAN/ZERO for a period of 2 … 3 seconds to GND via push button. At the end position
connect signal SPAN/ZERO for a period of 5 … 6 seconds to GND via a push button. The teached positions will be stored
non-volatile.
To reset the sensor to factory default signal ZERO/END must be connected to ground while powering up the sensor for
2 … 3 seconds.
DB-WB85-E-2013-11
8/17
www.asm-sensor.com
© ASM GmbH