English
Language : 

WB85 Datasheet, PDF (10/17 Pages) ASM GmbH – Analog Output
POSITAPE®
MSSI
Digital output SSI
MSSI
Synchronous serial SSI
Interface
Excitation voltage
Excitation current
Clock frequency
Code
Delay between pulse trains
Stability (temperature)
Operating temperature
Protection
EMC
Data format
(train of 26 pulses)
EIA RS-422
8 ... 36 V DC
typ. 19 mA at 24 V DC
typ. 35 mA at 12 V DC
max. 80 mA
100 kHz ... 500 kHz
Gray-Code, continuous progression
20 µs min.
±50 x 10-6 / °C f.s. (typical)
-40 ... +85 °C
Short circuit
EN 61326-1:2013
Recommended
processing circuit
DATA
DATA
CLOCK
Transmission
rate
Signal wiring/
Connection
CLOCK
Cable length
50 m
100 m
Signal
Excitation +
Excitation GND
CLOCK
CLOCK
DATA
DATA
−
−
Baud rate
100-400 kHz
100-300 kHz
Connector
Pin
1
2
3
4
5
6
7
8
Cable wire
color
white
brown
green
yellow
grey
pink
blu
red
Note:
Extension of the cable length will reduce
the maximum transmission rate.
View to sensor
connector
DB-WB85-E-2013-11
10/17
www.asm-sensor.com