English
Language : 

8205-10 Datasheet, PDF (2/4 Pages) ASM GmbH – MICRO HiCORDER

The Standard for Recorders
Depending on your application, select either the 8205-10 for general applications or the 8206-10 for power lines.
: For Recording AC Voltage, DC Voltage, or AC Current on a Single Channel
The 8205-10 can be used for basic recording in a wide range of applications, with
features such as a wide AC/DC measurement range of 0.1V to 500V, an analog level
monitor function, and a special clamp-on probe for recording large currents.
●Range:AC/DC 0.1V to 500V (AC 10A to 500A when using the 9651, AC 10A to 1000A when using
the 9668) ●Input Channels: One, for voltage or current
●Paper Feed Speed: 20 cm/min to 2 cm / hr ●Sampling Frequency: 10ms
Easy viewing of the
input level with a full-
range level monitor.
For DC measurement,
the zero position can
be changed in steps
that are -20% of the
range, which is convenient for tasks such as
recording both polarities.
Example of a level display for the DC 10V range
Measurements are possible
0%
from -9V to 11V by moving the
Standard position zero position.
11V
-40%
Intermediate position
• Range and mode setting data is
printed every 10 divisions.
• Voltage or current values can be
read directly from the vertical axis
0V
scale.
• Time is printed every 5 divisions.
• Interval printing of average values
on a grid with points every 2
divisions.
-80%
Minimum position
-9V
: For 2-Channel Special Purpose Recording of AC Voltage and Current from Power Lines
The 8206-10 provides simultaneous voltage and current measurement (a frequent requirement
of power line management) along with a zoom function that allows 2X recording centered
around the range value. Providing ranges that are expressly intended use with power lines, the
instrument is capable of recording voltages of up to 600V.
●Range: AC 100V, 200V, or 500V (AC 10A to 500A when using the 9651, AC 10A to 1000A when
using the 9668) ●Input Channels: Two, for simultaneous recording of voltage and current
●Paper Feed Speed: 60 cm/hr to 2 cm/hr ●Sampling Frequency: 10ms
For voltage measurements,
the display can be
expanded from 25% to
-35% around the center
of the range. The
center value can be
changed in steps that
are -10% of the range, which is convenient when
it is necessary to adjust the measurement position
for electric circuits with different rated voltages.
Example of a level display for the 200V range
Measurements are possible
from 90V to 290V by changing
the center value.
290V
0%
Standard position
+20%
Maximum position
• Range and mode setting data is
printed every 10 divisions.
• Voltage or current values can be
read directly from the vertical
axis scale.
• Time is printed every 5 divisions.
• Interval printing of average values
on a grid with points every 2
divisions.
-20%
Minimum position
200V
90V