English
Language : 

X3C25P1-02S Datasheet, PDF (17/18 Pages) Anaren Microwave – Tight Amplitude Balance
`
Model X3C25P1-02S
Rev B
Control Units
n=10
Control Units
n=10
Post Voltage RF Test
n=50
Thermal Cycle100 cycles -55° to
125°C. Dwell time= 30 min
n=40
Visual Inspection
n=50
Post Thermal RF Test
n=50
Moisture Resistance Testing -25° to 65°C for 2
hrs @ 90% humidity. Soak for 168 hrs at 90% to
85% humidity. Ramp temp to 25°C in 2 hrs @
90% humidity. Then soak @ -10°C for 3 hrs.
n=40
Post Moisture Resistance
RF Test n=50
Post Moisture Resistance
RF Test
n=50
Visual Inspection
n=50
Bake Units for 1 hour at
100° to 120°C
n=40
Post Bake RF Test
n=50
125% Power
Life Test 72 hrs
n=3
Final RF Test @ 25°C
n=25
Microsection
2 Life, 1 high power and
1 control
Control Units
n=10
Visual Inspection
n=30
Microsection
3 test units 1 control
Available on Tape
and Reel for Pick and
Place Manufacturing.
USA/Canada:
Toll Free:
Europe:
(315) 432-8909
(800) 411-6596
+44 2392-232392