English
Language : 

ALT6702 Datasheet, PDF (8/12 Pages) ANADIGICS, Inc – HELP4 UMTS PCS (Band 2) LTE/WCDMA/CDMA Multi-Mode PAM
ALT6702
APPLICATION INFORMATION
To ensure proper performance, refer to all related
Application Notes on the ANADIGICS web site:
http://www.anadigics.com
to the VMODE pins. The Bias Control table below lists
the recommended modes of operation for various
applications.
Shutdown Mode
The power amplifier may be placed in a shutdown mode
by applying logic low levels (see Operating Ranges
table) to the VEN, VMODE1 and VMODE2 voltages.
Bias Modes
The power amplifier may be placed in either Low,
Medium or High Bias modes by applying the
appropriate logic level (see Operating Ranges table)
Three operating modes are recommended to optimize
current consumption. High Bias/High Power operating
mode is for POUT levels > 16 dBm.At ~17dBm - 8 dBm,
the PA could be switched to Medium Power Mode. For
POUT levels < ~9 dBm, the PA could be switched to Low
Power Mode for extremely low current consumption.
APPLICATION
Low power
(Low Bias Mode)
Med power
(Medium Bias Mode)
High power
(High Bias Mode)
Shutdown
Table 7: Bias Control
POUT
LEVELS
BIAS
MODE
VEN
VMODE1
VMODE2
VCC
< +9 dBm
Low +1.8 V +1.8 V +1.8 V 3.1 - 4.35 V
> 8 dBm
< +17 dBm
Low
+1.8 V +1.8 V 0 V 3.1 - 4.35 V
> +16 dBm High +1.8 V 0 V
0 V 3.1 - 4.35 V
-
Shutdown 0 V
0V
0 V 3.1 - 4.35 V
VBATT
> 3.1 V
> 3.1 V
> 3.1 V
> 3.1 V
VVBABATTTT
CC55
22.2 µµFF
RFRINFIN
VMODE2
VMODE2
VMODE1
VMODE1
VEN
VEN
8
C1 C1
0.10µ.F1µF
GND aGt sNluDg at slug C3
33pF
V 1 VB1ATT BATT
VCC
10
VCC
10
2
RF2IN RFIN
RFOUT
9
RFOUT
9
3
4
5
VVVMME43NOODDEE21VVMMOODDEEC21 CPGLPNOLDUINT
8
7CPLIN
6GND
8CPLIN
7
5 VEN
CPLOUT 6
VCC
VCC
CC23 C4C2
C4
03.13µpFF 2.20µ.F1cµeFramic2.2µF ceramic
CPLIN
RFOUT
CPLOUT
RFOUT
CPLOUT
Figure 9: Evaluation Board Schematic
Data Sheet - Rev 2.5