English
Language : 

10-597107-171 Datasheet, PDF (68/73 Pages) Amphenol Corporation – Amphenol MIL-DTL-5015 and MIL-5015 Type Standard Cylindrical Connectors
MS/Standard
solder contacts
Machined copper alloy contacts in a full range of sizes, with closed
entry socket design in the size 12 and 16 contacts. A heavy silver-
plated finish is deposited on all MS style solder contacts for maximum
corrosion resistance, maximum current carrying capacity and low milli-
volt drop.
MS/STANDARD SOLDER CONTACTS*
Part
Number
Pin/
Socket
10-40569
Pin
10-597107-161 Socket
Mating
End
Size
16
Short†
Wire
Barrel
Size
16
10-40599
Pin
16 Long 16
10-597107-171 Socket
10-33646
Pin
12
12
10-597107-131 Socket
10-35531
Pin
8
8
10-35532
Socket
10-35529
Pin
4
4
10-35530
Socket
10-35527
Pin
0
0
10-35528
Socket
Allowable
Wire
Size
16
18
20
22
16
18
20
22
12
14
8
10
4
6
0
1
2
Test
Current**
Amps
13
10
7.5
5
13
10
7.5
5
23
17
46
33
80
60
150
125
100
* Solder Wells Filled
** Contact ratings as stated are test ratings only. The connector could not with-
stand full rated current through all contacts continuously. Please note that the
electrical data given is not an establishment of electrical safety factors. This is
left entirely in the designer’s hands as he can best determine which peak volt-
age, switching surges, transients, etc. can be expected in a particular circuit.
† The 10SL, 12S, 14S and 16S connectors require short contacts.
TABLE I
CONTACT ARRANGEMENT SERVICE RATING
MS
Service
Rating
Inst.
A
D
E
B
C
Recommended
Operating Voltage*
at Sea Level
DC
AC (RMS)
250
200
700
500
1250
900
1750
1250
2450
1750
4200
3000
Effective
Creepage
Distance
Nom.
1/16
1/8
3/16
1/4
5/16
1
Mechanical
Spacing
Nom.
1/16
1/8
3/16
1/4
5/16
* The values listed in Table I represent operating values which include a
generous safety factor. It may be necessary for some applications to
exceed the operating voltages listed here. If this is necessary, designers
will find Table II useful for determining the degree to which the recom-
mended values of Table I can be exceeded.
TABLE II
ALTITUDE VOLTAGE DERATING** CHART
MS
Service
Rating
Inst.
A
D
E
B
C
Nominal
Distance
Airspace
1/32
1/16
1/8
3/16
1/4
5/16
Creepage
1/16
1/8
3/16
1/4
5/16
1
Standard Sea
Level Conditions
Minimum
Flashover
Voltage
AC (RMS)
Test
Voltage
AC (RMS)
1400
1000
2800
2000
3600
2800
4500
3500
5700
4500
8500
7000
Pressure Altitude†
50,000 Feet
Minimum
Flashover
Voltage
AC (RMS)
Test
Voltage
AC (RMS)
500
400
800
600
900
675
1000
750
1100
825
1300
975
† Not corrected for changes in density due to variations in temperature.
** No attempt has been made to recommend operating voltages. The designer must determine his own
operating voltage by the application of a safety factor to the above derating chart to compensate for cir-
cuit transients, surges, etc.
Pressure Altitude†
70,000 Feet
Minimum
Flashover
Voltage
AC (RMS)
Test
Voltage
AC (RMS)
325
260
450
360
500
400
550
440
600
480
700
560
67