English
Language : 

ES1010SI Datasheet, PDF (4/11 Pages) Altera Corporation – 12V Hot-Swap Power Distribution Controllers
Page 4
Electrical Specifications
PARAMETER
VIN = 12V, TA = TJ = full temperature range, Unless Otherwise Specified.
SYMBOL
TEST CONDITIONS
MIN
(Note 4)
TYP
MAX
(Note 4)
EN Pull-Up Voltage
EN Rising Threshold
EN Hysteresis
VEN
VEN_THR
EN_HYS
EN Pin Open
2.5
3.2
-
1.1
1.7
2.35
125
170
250
EN Pull-Up Current
IEN
CURRENT REGULATION DURATION/POWER GOOD
12.6
17
24
CCLTIM Charging Current
CCLTIM Fault Pull-Up
Current (Note 4)
CCLTIM_ichg0
VCLTIM = 0V
17.2
20.5
25
-
20
-
Current Limit Time-Out
Threshold Voltage
CCLTIM_Vth
CLTIM Voltage
1.6
1.8
2.1
Power Good Pull Down
Current
PG_Ipd
VOUT = 0.5V
-
8
-
NOTES:
4. Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by
characterization and are not production tested.
Simplified Block Diagram
UNITS
V
V
mV
µA
µA
mA
V
mA
ISET-
ISEN+
- UV
+
+
VREF
-
VIN
+
-
+
POR
8V
-
QN R
R
QS
ENABLE
12V
EN
POK
GATE
GND
10µA
18V
UV DISABLE
OC +
-
7.5k
FALLING
EDGE
DELAY
ENABLE
+-
WOCLIM
CLIM
20µA
18V
20µA
+
-
+
1.86V
-
RISING
EDGE
PULSE
CLTIM
VIN
Description and Operation
The ES1010SI is targeted for +12V single power supply distribution control for generic hot swap switching applications.
This ICs features a highly accurate programmable current regulation (CR) level with programmable time delay to latch-off, and
programmable soft-start turn-on ramp all set with a minimum of external passive components. It also includes severe OC protection
ES1010SI 12V Hot-Swap Power Distribution Controllers
09617
March 14, 2014
March 2014 Altera Corporation
Rev A