bypass can be placed at the load as long as
there is sufficient separation between the VOUT
Sense point and the bulk capacitance. The
separation provides an inductance that isolates
the control loop from the bulk capacitance.
NOTE: Excess total capacitance on the output
(Output Filter + Bulk) can cause an over-
current condition at startup. Refer to the
EP53A7LQI/EP53A7HQI
section on Soft-Start for the maximum total
capacitance on the output.
NOTE: The Input and Output capacitors must
use a X5R or X7R or equivalent dielectric
formulation. Y5V or equivalent dielectric
formulations lose capacitance with frequency,
bias, and temperature and are not suitable for
switch-mode DC-DC converter filter applications.