EP4CGX75CF23C8N Datasheet, PDF (15/42 Pages) Altera Corporation – Cyclone IV Device Datasheet | |||
|
◁ |
Chapter 1: Cyclone IV Device Datasheet
1â15
Operating Conditions
Table 1â20. Differential I/O Standard Specifications for Cyclone IV Devices (1) (Part 2 of 2)
I/O Standard
VCCIO (V)
VID (mV)
Min Typ Max Min Max Min
VIcM (V) (2)
Condition
VOD (mV) (3)
VOS (V) (3)
Max Min Typ Max Min Typ Max
LVDS
(Column
I/Os)
0.05 DMAX ï£ 500 Mbps 1.80
2.375
2.5
2.625 100
â
0.55
500 Mbps ï£ DMAX
ï£ 700 Mbps
1.80 247
â
600 1.125 1.25 1.375
1.05 DMAX > 700 Mbps 1.55
BLVDS (Row
I/Os) (4)
2.375
2.5
2.625 100
â
â
â
â âââ â â â
BLVDS
(Column
2.375 2.5 2.625 100 â â
â
â âââ â â â
I/Os) (4)
mini-LVDS
(Row I/Os) 2.375 2.5 2.625 â â â
â
â 300 â 600 1.0 1.2 1.4
(5)
mini-LVDS
(Column
2.375 2.5 2.625 â â â
â
â 300 â 600 1.0 1.2 1.4
I/Os) (5)
RSDS® (Row
I/Os) (5)
2.375
2.5
2.625 â
â
â
â
â 100 200 600 0.5 1.2 1.5
RSDS
(Column
2.375 2.5 2.625 â â â
â
â 100 200 600 0.5 1.2 1.5
I/Os) (5)
PPDS (Row
I/Os) (5)
2.375
2.5
2.625 â
â
â
â
â 100 200 600 0.5 1.2 1.4
PPDS
(Column
2.375 2.5 2.625 â â â
â
â 100 200 600 0.5 1.2 1.4
I/Os) (5)
Notes to Table 1â20:
(1) For an explanation of terms used in Table 1â20, refer to âGlossaryâ on page 1â37.
(2) VIN range: 0 V ï£ VIN ï£ 1.85 V.
(3) RL range: 90 ï£ RL ï£ 110 ï .
(4) There are no fixed VIN, VOD , and VOS specifications for BLVDS. They depend on the system topology.
(5) The Mini-LVDS, RSDS, and PPDS standards are only supported at the output pins.
(6) The LVPECL I/O standard is only supported on dedicated clock input pins. This I/O standard is not supported for output pins.
May 2013 Altera Corporation
Cyclone IV Device Handbook,
Volume 3
|
▷ |