English
Language : 

EP220 Datasheet, PDF (14/16 Pages) Altera Corporation – Classic EPLDs
EP220 & EP224 Classic EPLDs
AC Operating Conditions: -7 & -10 Speed Grades Note (1)
Combinatorial Mode
Symbol
Parameter
tPD1
tPD2
tPZX
tPXZ
tOSR
tOSC
Input or I/O to non-registered output, inversion on, Note (2)
Input or I/O to non-registered output, inversion off, Note (2)
Input or I/O to output enable, Note (3)
Input or I/O to output disable, Note (3)
Register mode output-to-output skew
Combinatorial mode output-to-output skew
EP220-7
EP224-7
Min Max
7.5
8.5
9
9
300
400
EP220-10
EP224-10
Min Max
10
10
10
10
300
400
Units
ns
ns
ns
ns
ps
ps
Synchronous Clock Mode
Symbol
Parameter
fMAX
fCNT1
fCNT2
tSU1
tH
tCO1
tCO2
tCNT
tCL
tCH
tCP
Maximum frequency (pipelined), no feedback, Note (2)
Maximum counter frequency, external feedback, Note (2)
Maximum counter frequency, internal feedback, Note (2)
Input or I/O setup time to global clock
Input or I/O hold time from global clock
Global clock to output delay, Note (2)
Global clock to output delay through combinatorial macrocell
Minimum global clock period, Note (2)
Clock low time
Clock high time
Clock period
EP220-7
EP224-7
Min Max
100
74
100
7
0
6.5
11
10
4
4
10
EP220-10
EP224-10
Min Max
62.5
58.8
60.6
10
0
7
13
16.5
7
7
16
Units
MHz
MHz
MHz
ns
ns
ns
ns
ns
ns
ns
ns
Notes to tables:
(1) Operating conditions: VCC = 5 V ± 5%, TA = 0° C to 70° C for commercial use.
(2) Measured with three I/O outputs switching.
(3) The tPZX and tPXZ parameters are measured at ± 0.5 V from steady-state voltage that is driven by the specified
output load. The tPXZ parameter is measured with CL = 5 pF and with all eight outputs switching.
14
Altera Corporation