EP220 Datasheet, PDF (12/16 Pages) Altera Corporation – Classic EPLDs
EP220 & EP224 Classic EPLDs
ICC Supply Current: EP220-7A & EP224-7A
Symbol
Parameter
ICC3
VCC supply current
Note (5)
Conditions
fIN = 25 MHz, Note (9)
fIN = 100 MHz, Note (9)
Min
Max Unit
90
mA
115
mA
ICC Supply Current: EP220-10A, EP224-10A, EP220-12 & EP224-12 Note (5)
Symbol
Parameter
ICC1
VCC supply current (non-turbo)
ICC2
VCC supply current (non-turbo)
ICC3
VCC supply current (turbo, active)
Conditions
Min
Standby mode, Note (9)
VCC = Max., VIN = VCC or GND,
no load, fIN = 1 MHz, Notes (9), (10)
fIN = 15 MHz, Note (9)
fIN = 80 MHz, Note (9)
Max Unit
500
µA
5
mA
50
mA
60
mA
ICC Supply Current: EP220-7, EP224-7, EP220-10 & EP224-10 Note (5)
Symbol
Parameter
ICC1
VCC supply current (standby)
ICC3
VCC supply current (active)
Conditions
fIN = 25 MHz, Note (9)
fIN = 74 MHz, Note (9)
fIN = 25 MHz, Note (9)
fIN = 74 MHz, Note (9)
Min
Max Unit
90
µA
105
mA
115
mA
135
mA
Notes to tables:
(1) See Operating Requirements for Altera Devices in the Altera 1995 Data Book.
(2) Voltage with respect to ground.
(3) Minimum DC input is –0.5 V. During transitions, the inputs may undershoot to –2.0 V or overshoot to 7.0 V for
periods less than 20 ns under no-load conditions.
(4) Under bias. Extended temperature versions are also available.
(5) Operating conditions: TA = 0° C to 70° C, VCC = 5.0 V ± 5% for commercial use.
TA = –40° C to 85° C, VCC = 5.0 V ± 10% for industrial use.
(6) Absolute values with respect to device GND; all over- and undershoots due to system or tester noise are included.
(7) For -7A, -10A, -12 speed grades for EP220 and EP224 devices: maximum DC IOL (all 8 outputs) = 64 mA.
For -7, -10 speed grades for EP220 and EP224 devices: test 1 output at a time; test duration should not exceed 1 s.
(8) These values are measured during initial characterization. VCC = Max., VIN = VCC or GND.
(9) Measured with a device programmed as an 8-bit counter.
(10) When the Turbo Bit is not set (non-turbo mode), an EP220 or EP224 device enters standby mode if no logic
transitions occur for approximately 75 ns after the last transition.
12