English
Language : 

2031-A0023A Datasheet, PDF (6/20 Pages) Allen-Bradley – Safety Isolation System
Safety Isolation System
ElectroGuard
Combination Systems with Fusible Disconnect Switch
Product Selection: For North America (see page 12-19 for Ordering Instructions)
3-Phase Max. Hp
Rating (60Hz)
Catalogue Number ➋
Fuse
Amp.
Clip Type 1 General
Rating 200 230 460 575 Rating/
Purpose
(AC-3) V V V V Type ➊ Enclosure
Type 12 Dust
tight Enclosure
Type 12 Motor
Control Centre
Type Enclosure
(with bussing)
Type 4
Watertight
Painted Steel
Enclosure
Type 4X
Watertight
Stainless Steel
Enclosure
30A
Class J
2032-A0023A⊗-24J
2032-A0023J⊗-24J
2032-!0023J⊗-24J
2032-A0023F⊗-24J
2032-A0023C⊗-24J
23 5 7.5 15 15
60A
Class J
2032-A0023A⊗-25J
2032-A0023J⊗-25J
2032-!0023J⊗-25J
2032-A0023F⊗-25J
2032-A0023C⊗-25J
60A
Class J
2032-A0043A⊗-25J
2032-A0043J⊗-25J
2032-!0043J⊗-25J
2032-A0043F⊗-25J
2032-A0043C⊗-25J
43 10 15 30 30
100A
Class J
2032-A0043A⊗-26J
2032-A0043J⊗-26J
2032-!0043J⊗-26J
2032-A0043F⊗-26J
2032-A0043C⊗-26J
100A
Class J
2032-A0085A⊗-26J
2032-A0085J⊗-26J
2032-!0085J⊗-26J
2032-A0085F⊗-26J
2032-A0085C⊗-26J
85 25 30 60 60
200A
Class J
2032-A0085A⊗-27J
2032-A0085J⊗-27J
2032-!0085J⊗-27J
2032-A0085F⊗-27J
2032-A0085C⊗-27J
200A
Class J
2032-A0110A⊗-27J
2032-A0110J⊗-27J
2032-!0110J⊗-27J
2032-A0110F⊗-27J
2032-A0110C⊗-27J
110 40 40 75 100
400A
Class J
2032-A0110A⊗-28J
2032-A0110J⊗-28J
2032-!0110J⊗-28J
2032-A0110F⊗-28J
2032-A0110C⊗-28J
200A
Class J
2032-A0180A⊗-27J
2032-A0180J⊗-27J
2032-!0180J⊗-27J
2032-A0180F⊗-27J
2032-A0180C⊗-27J
180 50 60 125 150
400A
Class J
2032-A0180A⊗-28J
2032-A0180J⊗-28J
2032-!0180J⊗-28J
2032-A0180F⊗-28J
2032-A0180C⊗-28J
210
60
75
150
200
400A
Class J
2032-A0210A⊗-28J
2032-A0210J⊗-28J
2032-!0210J⊗-28J
2032-A0210F⊗-28J 2032-A0210C⊗-28J
400A
Class J
2032-A0300A⊗-28J
2032-A0300J⊗-28J
2032-!0300J⊗-28J
2032-A0300F⊗-28J
2032-A0300C⊗-28J
300 75 125 250 300
600A
Class J
2032-A0300A⊗-29J
2032-A0300J⊗-29J
2032-!0300J⊗-29J
2032-A0300F⊗-29J
2032-A0300C⊗-29J
600A
Class J
2032-A0420A⊗-29J
2032-A0420J⊗-29J
2032-!0420J⊗-29J
2032-A0420F⊗-29J
2032-A0420C⊗-29J
420 150 175 350 400
800A
Class L
2032-A0420A⊗-30L
2032-A0420J⊗-30L
2032-!0420J⊗-30L
2032-A0420F⊗-30L
2032-A0420C⊗-30L
800A
Class L
2032*-A0630A⊗-30L 2032*-A0630J⊗-30L
2032-!0630J⊗-30L
2032*-A0630F⊗-30L 2032*-A0630C⊗-30L
630 200 250 500 600
2000A
Class L
2032*-A0630A⊗-34L 2032*-A0630J⊗-34L
2032-!0630J⊗-34L
2032*-A0630F⊗-34L 2032*-A0630C⊗-34L
860
250
300
600
700
2000A
Class L
2032*-A0860A⊗-34L 2032*-A0860J⊗-34L
2032-!0860J⊗-34L
2032*-A0860F⊗-34L 2032*-A0860C⊗-34L
1200
450
450
900
900
2000A
Class L
2032*-A1200A⊗-34L 2032*-A1200J⊗-34L
2032-!1200J⊗-34L
2032*-A1200F⊗-34L 2032*-A1200C⊗-34L
To order the Time Delay feature, add the following Catalogue String to the end of the Cat. No. shown in the table:
Factory set 30 second time delay feature:
-1TD
Example: Catalogue Number 2032-A0180A⊗-27J becomes Catalogue Number 2032-A0180A⊗-27J-1TD to include the time delay feature.
* Input Power Feed Catalogue Number Code
The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.
Example: Catalogue Number 2032*-A0630J⊗-30L becomes Catalogue Number 2032T-A0630J⊗-30L for a “Top Feed” input power requirement.
Input Power Feed
Catalogue Number Code
Top Feed
T
Bottom Feed
B
➊ Power fuses are not included with the disconnect switch. Select power fuses in accordance with applicable local codes.
➋ Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine operator
to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the “Off” position.
Consult your local Rockwell Automation sales office for other time settings.
12-6