English
Language : 

2031-A0023A Datasheet, PDF (10/20 Pages) Allen-Bradley – Safety Isolation System
Safety Isolation System
ElectroGuard
Combination Systems with Thermal-magnetic Circuit Breaker
Product Selection for North America (see page 12-19 for Ordering Instructions)
3-Phase Max. Hp Rating
(60Hz)
Catalogue Number ➊
Ampere
Rating
(AC-3)
23
43
85
110
180
210
300
200V
5
-
-
-
7.5
10
-
-
-
-
15
20
25
-
-
-
-
30
40
-
-
50
-
-
-
-
60
-
-
-
75
100
-
230V
5
7.5
-
-
-
10
15
-
-
-
-
20
25
30
-
-
-
-
40
-
-
50
60
-
-
-
-
75
-
-
-
100
125
460V
5
7.5
10
15
-
-
-
20
25
30
-
-
-
-
40
50
60
-
-
75
-
-
-
100
125
150
-
-
-
-
-
-
-
575V
5
7.5
10
15
-
-
-
20
25
30
-
-
-
-
40
50
60
-
-
75
100
-
-
-
125
150
-
-
175
200
-
-
-
Type 1 General
Purpose
Enclosure
2033-A0023A⊗-39
2033-A0023A⊗-40
2033-A0023A⊗-41
2033-A0023A⊗-42
2033-A0043A⊗-40
2033-A0043A⊗-41
2033-A0043A⊗-42
2033-A0043A⊗-43
2033-A0043A⊗-44
2033-A0043A⊗-45
2033-A0085A⊗-42
2033-A0085A⊗-43
2033-A0085A⊗-44
2033-A0085A⊗-45
2033-A0085A⊗-46
2033-A0085A⊗-47
2033-A0085A⊗-48
2033-A0110A⊗-45
2033-A0110A⊗-46
2033-A0110A⊗-49
2033-A0110A⊗-50
2033-A0180A⊗-47
2033-A0180A⊗-48
2033-A0180A⊗-50
2033-A0180A⊗-51
2033-A0180A⊗-52
2033-A0210A⊗-48
2033-A0210A⊗-49
2033-A0210A⊗-53
2033-A0210A⊗-54
2033-A0300A⊗-49
2033-A0300A⊗-50
2033-A0300A⊗-51
Type 12
Dust tight
Enclosure
2033-A0023J⊗-39
2033-A0023J⊗-40
2033-A0023J⊗-41
2033-A0023J⊗-42
2033-A0043J⊗-40
2033-A0043J⊗-41
2033-A0043J⊗-42
2033-A0043J⊗-43
2033-A0043J⊗-44
2033-A0043J⊗-45
2033-A0085J⊗-42
2033-A0085J⊗-43
2033-A0085J⊗-44
2033-A0085J⊗-45
2033-A0085J⊗-46
2033-A0085J⊗-47
2033-A0085J⊗-48
2033-A0110J⊗-45
2033-A0110J⊗-46
2033-A0110J⊗-49
2033-A0110J⊗-50
2033-A0180J⊗-47
2033-A0180J⊗-48
2033-A0180J⊗-50
2033-A0180J⊗-51
2033-A0180J⊗-52
2033-A0210J⊗-48
2033-A0210J⊗-49
2033-A0210J⊗-53
2033-A0210J⊗-54
2033-A0300J⊗-49
2033-A0300J⊗-50
2033-A0300J⊗-51
Type 12 Motor
Control Centre
Type Enclosure
(with bussing)
2033-!0023J⊗-39
2033-!0023J⊗-40
2033-!0023J⊗-41
2033-!0023J⊗-42
2033-!0043J⊗-40
2033-!0043J⊗-41
2033-!0043J⊗-42
2033-!0043J⊗-43
2033-!0043J⊗-44
2033-!0043J⊗-45
2033-!0085J⊗-42
2033-!0085J⊗-43
2033-!0085J⊗-44
2033-!0085J⊗-45
2033-!0085J⊗-46
2033-!0085J⊗-47
2033-!0085J⊗-48
2033-!0110J⊗-45
2033-!0110J⊗-46
2033-!0110J⊗-49
2033-!0110J⊗-50
2033-!0180J⊗-47
2033-!0180J⊗-48
2033-!0180J⊗-50
2033-!0180J⊗-51
2033-!0180J⊗-52
2033-!0210J⊗-48
2033-!0210J⊗-49
2033-!0210J⊗-53
2033-!0210J⊗-54
2033-!0300J⊗-49
2033-!0300J⊗-50
2033-!0300J⊗-51
Type 4 Watertight
Painted Steel
Enclosure
2033-A0023F⊗-39
2033-A0023F⊗-40
2033-A0023F⊗-41
2033-A0023F⊗-42
2033-A0043F⊗-40
2033-A0043F⊗-41
2033-A0043F⊗-42
2033-A0043F⊗-43
2033-A0043F⊗-44
2033-A0043F⊗-45
2033-A0085F⊗-42
2033-A0085F⊗-43
2033-A0085F⊗-44
2033-A0085F⊗-45
2033-A0085F⊗-46
2033-A0085F⊗-47
2033-A0085F⊗-48
2033-A0110F⊗-45
2033-A0110F⊗-46
2033-A0110F⊗-49
2033-A0110F⊗-50
2033-A0180F⊗-47
2033-A0180F⊗-48
2033-A0180F⊗-50
2033-A0180F⊗-51
2033-A0180F⊗-52
2033-A0210F⊗-48
2033-A0210F⊗-49
2033-A0210F⊗-53
2033-A0210F⊗-54
2033-A0300F⊗-49
2033-A0300F⊗-50
2033-A0300F⊗-51
Type 4X
Watertight
Stainless Steel
Enclosure
2033-A0023C⊗-39
2033-A0023C⊗-40
2033-A0023C⊗-41
2033-A0023C⊗-42
2033-A0043C⊗-40
2033-A0043C⊗-41
2033-A0043C⊗-42
2033-A0043C⊗-43
2033-A0043C⊗-44
2033-A0043C⊗-45
2033-A0085C⊗-42
2033-A0085C⊗-43
2033-A0085C⊗-44
2033-A0085C⊗-45
2033-A0085C⊗-46
2033-A0085C⊗-47
2033-A0085C⊗-48
2033-A0110C⊗-45
2033-A0110C⊗-46
2033-A0110C⊗-49
2033-A0110C⊗-50
2033-A0180C⊗-47
2033-A0180C⊗-48
2033-A0180C⊗-50
2033-A0180C⊗-51
2033-A0180C⊗-52
2033-A0210C⊗-48
2033-A0210C⊗-49
2033-A0210C⊗-53
2033-A0210C⊗-54
2033-A0300C⊗-49
2033-A0300C⊗-50
2033-A0300C⊗-51
➊ Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine
operator to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the “Off”
position. See next page for instructions on how to order the optional time delay feature. Consult your local Rockwell Automation sales office for other time settings.
12-10