Product Selection: For North America (see page 12-19 for Ordering Instructions)
3-Phase Max. Hp Rating (60Hz)
Catalogue Number â
Ampere
Rating
(AC-3)
23
43
85
110
180
210
300
420
630
860
1200
200V
5
10
25
40
50
60
100
150
200
250
450
230V
7.5
15
30
40
60
75
125
175
250
300
450
460V
15
30
60
75
150
-
250
350
500
600
900
575V
15
30
60
100
150
200
300
400
600
700
900
Type 1 General
Purpose
Enclosure
2031-A0023Aâ
2031-A0043Aâ
2031-A0085Aâ
2031-A0110Aâ
2031-A0180Aâ
2031-A0210Aâ
2031-A0300Aâ
2031-A0420Aâ
2031*-A0630Aâ
2031*-A0860Aâ
2031*-A1200Aâ
Type 12
Dust tight
Enclosure
2031-A0023Jâ
2031-A0043Jâ
2031-A0085Jâ
2031-A0110Jâ
2031-A0180Jâ
2031-A0210Jâ
2031-A0300Jâ
2031-A0420Jâ
2031*-A0630Jâ
2031*-A0860Jâ
2031*-A1200Jâ
Type 12 Motor
Control Centre
Type Enclosure
(with bussing)
2031-!0023Jâ
2031-!0043Jâ
2031-!0085Jâ
2031-!0110Jâ
2031-!0180Jâ
2031-!0210Jâ
2031-!0300Jâ
2031-!0420Jâ
2031-!0630Jâ
2031-!0860Jâ
2031-!1200Jâ
Type 4
Watertight
Painted Steel
Enclosure
2031-A0023Fâ
2031-A0043Fâ
2031-A0085Fâ
2031-A0110Fâ
2031-A0180Fâ
2031-A0210Fâ
2031-A0300Fâ
2031-A0420Fâ
2031*-A0630Fâ
2031*-A0860Fâ
2031*-A1200Fâ
Type 4X
Watertight
Stainless Steel
Enclosure
2031-A0023Câ
2031-A0043Câ
2031-A0085Câ
2031-A0110Câ
2031-A0180Câ
2031-A0210Câ
2031-A0300Câ
2031-A0420Câ
2031*-A0630Câ
2031*-A0860Câ
2031*-A1200Câ
To order the Time Delay feature, add the following Catalogue String to the end of the Catalogue Number shown in the
table:
Factory set 30 second time delay feature:
-1TD
Example: Catalogue Number 2031-A0180Aâ becomes Catalogue Number 2031-A0180Aâ-1TD to include the time delay feature.
* Input Power Feed Catalogue Number Code
The Catalogue Number as listed is incomplete. Select an Input Power Feed Code from the table below.
Example: Catalogue Number 2031*-A0630Jâ becomes Catalogue Number 2031T-A0630Jâ for a âTop Feedâ input power requirement.
Input Power Feed
Top Feed
Bottom Feed
Catalogue Number Code
T
B
! Bussing Designation
The Catalogue Number as listed is incomplete. Select a Bussing Designation Code from the table below.
Example: Catalogue Number 2031-!0085Jâ becomes Catalogue Number 2031-M0085Jâ for â600A Line Side Incoming Bus and Outgoing Power Cablesâ
bussing designation.
Type of Bussing â
Catalogue Number Code
600A Line Side Incoming Bus and Outgoing Power Cables
M
1200A Line Side Incoming Bus and Outgoing Power Cables
S
Line Side Incoming Power Cables and 600A Load Side Outgoing Bus
F
Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus
B
â Input Line Voltage Code
The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below.
Example: Catalogue Number 2031-A0085Jâ becomes Catalogue Number 2031-A0085JB for a 480V 60Hz Input Line Voltage application.
Input Line Voltage
208V 60Hz 240V 60Hz 480V 60Hz 600V 60Hz
Voltage Code for Catalogue Number
H
A
B
C
â Optional Time Delay Feature. The Safety Isolation System may be ordered with a factory set time delay feature (30 seconds) in order to allow time for the machine
operator to shut-down drives or other equipment that requires a controlled stop, after the operating handle on a Remote Lockout Station has been moved to the âOffâ
position. Consult your local Rockwell Automation sales office for other time settings.
â Bus Type: Copper with tin plating. Consult factory for other types of bussing.
12-4
|
▷ |