English
Language : 

800EP-MTS44 Datasheet, PDF (5/7 Pages) Allen-Bradley – Push Buttons
Emergency Stop Devices
Push Buttons
800 E-Stops
Product Selection—30.5mm
Emergency Stop Operators — 2-Position Red Non Illuminated
2-Position Push-Pull
Operator Position
2-Position Push-Pull/Twist
Contacts Maintained Out Maintained In
Enclosure
Protection
Release
Catalogue Number
N.C.L.B. ! Closed Open
Type 4 & 13
Type 4, 4X & 13
Push-Pull
Push-Pull/Twist
800T-FX6D4
800T-FXT6D4
800H-FRXT6D4
N.O. Open Closed
N.C.L.B. ! Closed Open
Type 4 & 13
Type 4, 4X & 13
Push-Pull
Push-Pull/Twist
800T-FX6A1
800T-FXT6A1
800H-FRXT6A1
N.C.L.B.! Closed Open
N.C.L.B.! Closed Open
Type 4 & 13
Type 4, 4X & 13
Push-Pull
Push-Pull/Twist
800T-FX6A5
800T-FXT6A5
800H-FRXT6A5
S.M.C.B. ➊➋ Closed Open
Type 4 & 13
Type 4, 4X & 13
Push-Pull
Push-Pull/Twist
800TC-FX6D4S
800TC-FXT6D4S
800HC-FRXT6D4S
N.O. Open Closed
S.M.C.B. ➊➋ Closed Open
Type 4 & 13
Type 4, 4X & 13
Push-Pull
Push-Pull/Twist
800TC-FX6A1S
800TC-FXT6A1S
800HC-FRXT6A1S
S.M.C.B. Closed Open
S.M.C.B.➊➋ Closed Open
Type 4 & 13
Type 4, 4X & 13
Push-Pull
Push-Pull/Twist
800TC-FX6A5S
800TC-FXT6A5S
800HC-FRXT6A5S
Note: Emergency stop push buttons are compliant with EN-418 and IEC 60947-5-5 Standards when using N.C.L.B. contact blocks.
➊ Normally closed late break contact. When button is pushed from the OUT to IN position, the mechanical detent action of the operator occurs before electrical contacts
change state. When the button is pulled from the IN to the OUT position, the electrical contacts change state before the mechanical detent occurs.
➋ The Self-Monitoring Contact Block (S.M.C.B.) is composed of a N.C.L.B. contact wired in series with a N.O. monitoring contact. The N.O. monitoring contact automatically
closes when the S.M.C.B. is properly installed onto the E-Stop operator. If the S.M.C.B. is separated from the E-Stop operator, the N.O. monitoring contact will
automatically open.
6-18