English
Language : 

AKD4588 Datasheet, PDF (9/46 Pages) Asahi Kasei Microsystems – Evaluation board Rev.C for AK4588
ASAHI KASEI
[AKD4588]
AK4588 (ADC/DAC) part Control Program Operation Manual
„ Set-up of evaluation board and control software
This evaluation board does not support to I2C control.
1. Set up the AKD4588 according to above mentioned setting.
2. Connect IBM-AT compatible PC with AKD4588 by 10-line type flat cable (packed with AKD4588). Take care of
the direction of 10pin header. (Please install the driver in the CD-ROM-disk when this control software is used on
Windows 2000/XP. Please refer “Installation Manual of Control Software Driver by AKM device control software”.
In case of Windows95/98/ME, this installation is not needed. This control software does not operate on Windows
NT.)
3. Insert the CD-ROM-disk labeled “AKD4588 Control Program ver 1.0” into the CD-ROM-disk drive.
4. Access the CD-ROM-disk drive and double-click the icon of “AKD4588 (DIR/DIT)-1.exe” (address 00H-0FH) to
set up the control program.
5. Then please evaluate according to the followings.
Attention: Please use fixed “CAD1-0=01”.
„ Operation flow
Keep the following flow.
1. Set up the control program.
2. Then set up the dialog and input data.
If you want to write the input data to AK4588, click “OK” button. If not, click “Cancel” button.
„ Explanation of each buttons
1. [Port Setup]: Set up the printer port.
2. [Write default]: Initialize the register of AK4588.
3. [Function1]: Dialog to write data by keyboard operation.
4. [Function2]: Dialog to evaluate IPGA and ATTL/ATTR/ATTM.
5. [Write]:
Write data to each register.
„ Explanation of each dialog
1. [Function1 Dialog]: Dialog to write data by keyboard operation
Address Box: Input registers address in 2 figures of hexadecimal.
Data Box:
Input registers data in 2 figures of hexadecimal.
If you want to write the input data to AK4588, click “OK” button. If not, click “Cancel” button.
2. [Function2 Dialog]: Dialog to evaluate IPGA and ATTL/ATTR/ATTM
This dialog corresponds to only addr=0BH, 0CH and 0DH.
Address Box: Input register address in 2 figures of hexadecimal.
<KM073800>
-9-
2004/02