2. Control Software Manual
n Set-up of evaluation board and control software
1. Set up the AKD4562 according to previous term.
2. Connect IBM-AT compatible PC with AKD4562 by 10-line type flat cable (packed with AKD4562). Take care of the
direction of 10pin header. (This control software does not operate on Windows NT, therefore please operate it on
Windows95/98.)
3. Insert the floppy-disk labeled “AKD4562 Control Program ver 1.0” into the floppy-disk drive.
4. Access the floppy-disk drive and double-click the icon of “AKD4562.exe” to set up the control program. This
software corresponds to only AKM mode.
5. Then please evaluate according to the follows.
n Explanation of each buttons
1. [Port Setup] :
2. [Reset] :
3. [Function1] :
4. [Function2] :
5. [Write] :
Set up the printer port.
Initialize the register of AK4562.
Dialog to write data by keyboard operation.
Dialog to evaluate IPGA and OPGA.
Dialog to write data by mouse operation.
Note : AK4353(DIT) is fixed to MCLK=256fs and I2S compatible mode. Therefore, in the case of evaluation for
AK4562’s ADC, it is necessary for AK4562 to set up MCLK=256fs and I2S compatible mode.
n Explanation of each dialog
1. [Function1 Dialog] : Dialog to write data by keyboard operation
Address Box: Input register address in 2 figures of hexadecimal.
Data Box:
Input register data in 2 figures of hexadecimal.
If you want to write the input data to AK4562, click “OK” button. If not, click “Cancel” button.
<KM061600>
-9-