AKD4112B Datasheet, PDF (6/17 Pages) Asahi Kasei Microsystems – AKD4112B EVALUATION BOARD | |||
|
◁ |
ASAHI KASEI
[AKD4112B]
AKD4112B Control Program operation manual
n Set-up of evaluation board and control software
1. Set up the AKD4112B according to previous term.
2. Connect IBM-AT compatible PC with AKD4112B by 10-line type flat cable (packed with AKD4112B). Take care of
the direction of 10pin header. (Please install the driver in the floppy-disk when this control software is used on
Windows 2000/XP. Please refer âInstallation Manual of Control Software Driver by AKM device control softwareâ.
In case of Windows95/98/ME, this installation is not needed. This control software does not operate on Windows
NT.)
3. Insert the CD-ROM labeled âAK4112B Evaluation Kitâ into the CD-ROM drive.
4. Access the CD-ROM drive and double-click the icon of âakd4112Bâto set up the control program.
5. Then please evaluate according to the follows.
n Operation flow
Keep the following flow.
1. Set up the control program according to explanation above.
2. Click âPort Setupâ button.
3. Then set up the dialog and input data.
n Explanation of each buttons
1. [Port Setup] : set up the printer port.
2. [Write default] : initialize the register of AK4112B.
3. [All read] : read all registers.
4. [Read] : read data from each register.
5. [Write] : write data to each register.
If you want to write the input data to AK4112B, click âOKâ button. If not, click âCancelâ button.
n Indication of data
Input data is indicated on the register map. Red letter indicates âHâ or â1â and blue one indicates âLâ or â0â. Blank is the
part that is not defined in the datasheet.
End.
<KM065901>
-6-
2002/12
|
▷ |