English
Language : 

AK2573A Datasheet, PDF (30/38 Pages) Asahi Kasei Microsystems – 125M / 156M Laser Diode Driver + APC
ASAHI KASEI
[AK2573A]
8.2.6 Data Change
The SDA pin is normally pulled high with 4.7k to 10kΩ. Data on the SDA pin may change only during SCL low time
period. Data changes during SCL high periods will indicate a start or stop condition.
SCL
SDA
Data
Stable
Data
Change
8.2.7 Start / Stop Condition
Start Condition: A high-to-low transition of SDA with SCL high is a start condition that must precede any other
command.
Stop Condition: A high-to-low transition of SDA with SCL high is a stop condition.
SCL
SDA
START
STOP
<MS0189-E-01>
-30-
2004/5