English
Language : 

AKD5388-A Datasheet, PDF (22/36 Pages) Asahi Kasei Microsystems – AK5388 Evaluation Board Rev.4
[AKD5388-A]
Revision History
Date
(yy/mm/dd)
07/06/27
08/02/12
08/07/07
08/11/04
09/01/05
09/03/02
Manual
Revision
KM090200
KM090201
KM090202
KM090203
KM090204
KM090205
Board
Revision
0
1
2
3
3
4
Reason
First Edition
Change
Change
Modification
Change
Modification
Change
Change
Modification
Modification
Modification
Change
Page
Contents
8
9-21
9-21
9-21
10,14,
18
9-21
Device revision was changed. Rev. A -> Rev. C
Circuit diagram was changed.
R: 91ohm -> 10ohm, OP-amp: LME49710-> NJM5534D
PORT1, PORT2: TOTX197-> TOTX176
Update of measurement results
Device revision was changed. Rev. C -> Rev. D
Update of measurement results
Device revision was changed. Rev. D -> Rev. E
Circuit diagram was changed.
R300, R301:Add 20ohm, C300, C301:Add 220pF.
R1300, R1301:Add 20ohm, C1300, C1301:Add 220pF.
Update of measurement results
Update of Plots.
Figure 3, Figure 11, Figure 19
Update of measurement results
Circuit diagram was changed.
C300,C301,C1300,C1301:Deleted
C121,C122,C123,C124,C1121,C1122,C1123,C1124
:24.2nF -> 15nF
C3,C4,C1003,C1004: 10uF -> 100uF
R15,R17,R19,R21: 10kohm -> 11kohm
IMPORTANT NOTICE
These products and their specifications are subject to change without notice.
When you consider any use or application of these products, please make inquiries the sales office of Asahi Kasei
EMD Corporation (AKEMD) or authorized distributors as to current status of the products.
AKEMD assumes no liability for infringement of any patent, intellectual property, or other rights in the application or
use of any information contained herein.
Any export of these products, or devices or systems containing them, may require an export license or other official
approval under the law and regulations of the country of export pertaining to customs and tariffs, currency exchange,
or strategic materials.
AKEMD products are neither intended nor authorized for use as critical componentsNote1) in any safety, life support, or
other hazard related device or systemNote2), and AKEMD assumes no responsibility for such use, except for the use
approved with the express written consent by Representative Director of AKEMD. As used here:
Note1) A critical component is one whose failure to function or perform may reasonably be expected to result,
whether directly or indirectly, in the loss of the safety or effectiveness of the device or system containing it, and
which must therefore meet very high standards of performance and reliability.
Note2) A hazard related device or system is one designed or intended for life support or maintenance of safety or
for applications in medicine, aerospace, nuclear energy, or other fields, in which its failure to function or perform
may reasonably be expected to result in loss of life or in significant injury or damage to person or property.
It is the responsibility of the buyer or distributor of AKEMD products, who distributes, disposes of, or otherwise
places the product with a third party, to notify such third party in advance of the above content and conditions, and the
buyer or distributor agrees to assume any and all responsibility and liability for and hold AKEMD harmless from any
and all claims arising from the use of said product in the absence of such notification.
<KM090205>
- 22 -
2009/03