AKD4710-A Datasheet, PDF (14/30 Pages) Asahi Kasei Microsystems – AK4710 Evaluation Board Rev.1 | |||
|
◁ |
ASAHI KASEI
[AKD4710-A]
 Video
[Measurement condition]
⢠Signal Generator : Tektronix TG2000
: Tektronix TG700 (for S/N measurement)
⢠Measurement unit : Tektronix VM700T
⢠Power Supply : VP=12V, VD1=3.3V, VD2=3.3V, VDD1=3.3V, VDD2=3.3V
⢠Interface
: Input: BNC, Output: BNC
⢠Temperature : Room
⢠Measurement signal line path: S/N: ENCV â TVVOUT
Y/C Crosstalk: ENCV â TVVOUT, ENCRC â TVRC
DG, DP: ENCV â TVVOUT
Parameter
Input Signal
Measurement Filter
Results
Unit
S/N
0% Flat Field
BW=15kHz to 5MHz
76.1
dB
Filter=Uni-Weighted
Y/C Crosstalk
100% Red Field
BW=15kHz to Full
-59.5
dB
(Measured at TVVOUT) (YÃENCV, CÃENCRC)
(Note1)
DG
Modulated 5 step
Min: -0.31
%
Max: 0.00
DP
Modulated 5 step
Min: -0.93
deg.
Max: 0.11
Plots
Figure 2-1. Noise spectrum (Input=0% Flat Field, BW=15kHz to 5MHz, Filter=Uni-Weighted)
Figure 2-2. Y/C Crosstalk (Measured at TVVOUT, Input= 100% Red, ENCV=Y, ENCRC=C), BW=15kHz to Full)
Figure 2-3. DG, DP (Input= Modulated 5 step)
(Note1) Y/C Crosstalk: Reference Measurement: Results: 1.7dB (p-p)
Composite signalÃENCV, no inputÃENCRC, TVRC is terminated by 75Ohm.
Y/C Crosstalk: Measurement: Results: -57.8dB (p-p)
YÃENCV, CÃENCRC, TVRC is terminated by 75Ohm.
Y/C Crosstalk calculation: -57.8dB (p-p) â 1.7dB (p-p) = -59.5dB (p-p)
<KM105902>
- 14 -
2011/06
|
▷ |