1. [Function1 Dialog]: Dialog to write data by keyboard operation
Address Input Box : Input address of register which data should be written into,in 2 figures of hexadecimal.
Data Input Box : Input data which should be written into the register,in 2 figures of hexadecimal.
Click âOKâ button,if you write input data into register.
Click âCancelâ button,if you donât write input data into register.
2. [Function2 Dialog]: Dialog to evaluate ATT
This dialog corresponds to addr:02H, 03H,04H, 05H, 06H,07H, 0BH, 0CH.
Address Input Box: Input address of register which data should be written into,in 2 figures of hexadecimal.
Start Data Input Box:Input first data (start data) which should be written into the register,
in 2 figures of hexadecimal.
End Data Input Box: Input last data (end data) which should be written into the register,
in 2 figures of hexadecimal.
Interval Input Box: Input time distance (interval time) between write and write when data is written into the
register,in decimal. Unit of time is ms.
Step Input Box: Input value distance (step of data) between data and data when data is written into the register,
in decimal.
Mode Select Check Box:Select mode of data flow, âData returns to start data after data reached end data.â
Or âData flow is end when data reached end data.â
Set mode of data flow by checked or no into this check box.
When you checked into this: Data returns to start data after data reached end data.
When you did not check into this: Data flow is end when data reached end data.
[Example When you checked into this] Start Data = 00, End Data = 09
Data flow: 00 01 02 03 04 05 06 07 08 09 09 08 07 06 05 04 03 02 01 00
[Example When you did not check into this] Start Data = 00, End Data = 09
Data flow: 00 01 02 03 04 05 06 07 08 09
Click âOKâ button,if you write input data into register.
Click âCancelâ button,if you donât write input data into register.
3. [Write Dialog]: Dialog to write data by mouse operation
There are dialogs corresponding to each register.
Click the âWriteâ button corresponding to each register to set up the dialog.
If you check the check box, data becomes âHâ or â1â. If not, âLâ or â0â.
Click âOKâ button,if you write input data into register.
Click âCancelâ button,if you donât write input data into register.
 Indication of data
Input data is indicated on the register map.
Red letter indicates âHâ or â1â and blue letter indicates âLâ or â0â.
Blank is the part that is not defined in the datasheet.
 Attention on the operation
Input data to all boxes when you have set up âFunction1 dialogâ or âFunction2 dialogâ. An âattention dialogâ is indicated
if you input data or address that is not specified in the datasheet or you click âOKâ button before you input data. In that case
set up the dialog and input data once more again. These operations does not need if you click âCancelâ button or check the
check box.
<KM076201>
- 12 -
2005/07
|
▷ |