English
Language : 

AK4185-A Datasheet, PDF (11/18 Pages) Asahi Kasei Microsystems – Evaluation board
[AKD4185-A]
4. Setting of measurement mode.
(4-1) External Clock Mode
When any other item is selected from the drop-down list of “1st Measurement” except the item of
“INTERNAL”, it becomes the external clock mode.
(4-1-1) Single Read
Write “Single” in line [00H] column F2 of the “Register Setup”, it becomes the single read mode. The
number of measurement can be set by “# repetition” and the number of clocks of each measurement can be
changed by “Clock/Conversion”.
(4-1-2) Continuous Read
Write “Continuous” in line [00H] column F2 of the “Register Setup”, it becomes the continuous read
mode. The number of measurement can be set in line [00H] column F1 of the “Register Setup”.
(4-2) Internal Clock Mode
When the item of “INTERNAL” is selected from the drop-down list of “1st Measurement”, it becomes the
internal clock mode. The setup of the internal mode is at line [01H] and [02H] of the “Register Setup”.
5. Drawing function.
When button [DRAWLINE] is pushed, the dialog of the drawing function as shown in Figure 6 is opened.
Figure 6. Touch Screen window
[START] :
[Paint/Locate] :
[STOP] :
[Pen Color] :
[Close] :
The scanning of the touch panel begins and the screen is cleared when [START] being pushed
again.
When it sets to Paint, and tracing on the touch panel, tracks are displayed on Window.
When it sets to Locate, and tracing on the touch panel, the mouse cursor on Window moves.
(Shortcut key: Ctrl)
The draw function is stopped.
The color of the pen is displayed on time.
Returns to the main dialog.
<KM090700>
- 11 -
2007/11