AK4185-A Datasheet, PDF (10/18 Pages) Asahi Kasei Microsystems – Evaluation board | |||
|
◁ |
[AKD4185-A]
1. The setup of the AK4185âs register.
[Write] : Write registers that is currently displayed.
[Read] : Read registers that is currently displayed.
[Addr] 00H: Check the box, data becomes âHâ or â1â. If not becomes âLâ or â0â.
00H-03H: Select data from drop-down list.
* As for the AK4185âs register definitions, refer to datasheet of the AK4185.
2. 4-Wire Touch Screen position, pressure and temperature measurement.
Please set the AK4185âs register to 4-Wire Touch Screen Operation when using 4- Wire touch screen.
[START]: When select âChannel Selectionâ and click [START] button with pressing point by the status or
finger. The results of measurement are displayed at âAD OUT Sectionâ. Display all data on an
assistant window. The parameter on the âChannel Selectionâ corresponds to A2-0 bits, MODE bit
and PD bit of the AK4185âs control command.
<Example ʵ Touch-position measurement>
a. Select â4W-X-axisâ and â12 bitâ from drop-down list of â1st Measurementâ and â1st Modeâ.
Check the box of â1st PDâ.
b. Select â4W-Y-axisâ and â12 bitâ from drop-down list of â2nd Measurementâ and â1st Modeâ.
Check the box of â2nd PDâ.
c. Click [START] button with touching any position on Touch Screen, then start the measurement.
d. Display MEAN, MAX, MIN and SIGMA of measurement results at âAD OUT Sectionâ. (Left: X-axis
measurement results, Right: Y-axis measurement results) The results are displayed in decimal, and
maximum value is â4095â. Display data on assistant window. Line up X-axis data at first, next is
Y-axis.
<Example ʵ Touch-pressure measurement>
a. Select â4W-Z1â and â12 bitâ from drop-down list of â1st Measurementâ and â1st Modeâ.
Check the box of â1st PDâ.
b. Select â4W-Z2â and â12 bitâ from drop-down list of â2nd Measurementâ and â1st Modeâ.
Check the box of â2nd PDâ.
c. Click [START] button with touching any position on Touch Screen, then start the measurement.
d. Display touch-pressure measurement results at âPressureâ. Rtouch can be requested according to the
Rxplate. (Bottom: X-position and Y-position) The results are displayed in float. Display data on
assistant window. Line up Z1 data at first, next is Z2.
<Example ʵ Temperature measurement>
a. Select â4W-TEMP0â and â12 bitâ from drop-down list of â1st Measurementâ and â1st Modeâ.
Check the box of â1st PDâ.
b. Select â4W- TEMP1â and â12 bitâ from drop-down list of â2nd Measurementâ and â1st Modeâ.
Check the box of â2nd PDâ.
c. Click [START] button, then start the measurement.
d. Display temperature measurement results at âTemperatureâ. The results are displayed in float. Display
data on assistant window. Line up TEMP0 data at first, next is TEMP1.
3. 5-Wire Touch Screen position and temperature measurement.
Please set the AK4185âs register to 5-Wire Touch Screen Operation when using 5- Wire touch screen.
As for the measuring method of 5-Wire Touch Screen, refer to the position and the temperature measurement of
4-Wire touch screen.
* The measurement item âReservedâ is not used, Please do not select it.
<KM090700>
- 10 -
2007/11
|
▷ |