English
Language : 

AD9925 Datasheet, PDF (81/96 Pages) Analog Devices – CCD Signal Processor with Vertical Driver and Precision Timing Generator
AD9925
Table 68. Field 0 Register Map
Address Data Bit Content Default Value
D0
[3:0]
X
[4]
X
[5]
X
[9:6]
X
[10]
X
[11]
X
[15:12]
X
[16]
X
[17]
X
[21:18]
X
[22]
X
[23]
X
D1
[3:0]
X
[4]
X
[5]
X
[9:6]
X
[10]
X
[11]
X
[15:12]
X
[16]
X
[17]
X
[23:18]
D2
[11:0]
X
[23:12]
X
D3
[11:0]
X
[23:12]
X
D4
[11:0]
X
[23:12]
X
D5
[3:0]
X
[9:4]
X
[21:10]
[22]
D6
[11:0]
X
[23:12]
X
D7
[11:0]
X
[23:12]
X
Register Name
VSEQSEL0_0
SWEEP0_0
MULTI0_0
VSEQSEL1_0
SWEEP1_0
MULTI1_0
VSEQSEL2_0
SWEEP2_0
MULTI2_0
VSEQSEL3_0
SWEEP3_0
MULTI3_0
VSEQSEL4_0
SWEEP4_0
MULTI4_0
VSEQSEL5_0
SWEEP5_0
MULTI5_0
VSEQSEL6_0
SWEEP6_0
MULTI6_0
UNUSED
SCP1_0
SCP2_0
SCP3_0
SCP4_0
VDLEN_0
HDLAST_0
VPATSECOND_0
SGMASK_0
SGPATSEL_0
HDLAST13_0
SGLINE1_0
SGLINE2_0
SCP5_0
SCP6_0
Register Description
Selected Vertical Sequence for Region 0.
Select Sweep Region for Region 0. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 0. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 1.
Select Sweep Region for Region 1. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 1. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 2.
Select Sweep Region for Region 2. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 2. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 3.
Select Sweep Region for Region 3. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 3. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 4.
Select Sweep Region for Region 4. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 4. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 5.
Select Sweep Region for Region 5. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 5. 0 = No Multiplier, 1 = Multiplier.
Selected Vertical Sequence for Region 6.
Select Sweep Region for Region 6. 0 = No Sweep, 1 = Sweep.
Select Multiplier Region for Region 6. 0 = No Multiplier, 1 = Multiplier.
Unused.
Vertical Sequence Change Position No. 1 for Field 0.
Vertical Sequence Change Position No. 2 for Field 0.
Vertical Sequence Change Position No. 3 for Field 0.
Vertical Sequence Change Position No. 4 for Field 0.
VD Field Length (Number of Lines) for Field 0.
HD Line Length (Number of Pixels) for Last Line in Field 0.
Selected Second Vertical Pattern Group for VSG Active Line.
Masking of VSG Outputs during VSG Active Line.
Selection of VSG Patterns for Each VSG Output.
MSB for 13-Bit Last Line Length
VSG Active Line 1.
VSG Active Line 2
(If No Second Line Is Needed, Set to Same as Line 1 or Maximum).
Vertical Sequence Change Position No. 5 for Field 0.
Vertical Sequence Change Position No. 6 for Field 0.
Rev. A | Page 81 of 96