English
Language : 

PAC5220 Datasheet, PDF (56/73 Pages) Active-Semi, Inc – Power Application Controller
PAC5220
Power Application Controller
16.4. Electrical Characteristics
Table 16-1. Microcontroller and Clock Control System Electrical Characteristics
(VSYS = VCCIO = 5V, VCC33 = 3.3V, VCC18 = 1.8V, and TA = -40°C to 105°C unless otherwise specified.)
SYMBOL
PARAMETER
CONDITIONS
MIN
fHCLK
Microcontroller clock
HCLK
fFRCLK = fHCLK = fACLK = ROSC 11b, PLL
disabled, CPU halt; other clock sources,
ADC, timers, and serial interface disabled
fFRCLK = fHCLK = fACLK = ROSC 10, PLL
disabled, CPU halt; other clock sources,
ADC, timers, and serial interface disabled
fFRCLK = fHCLK = fACLK = ROSC 01, PLL
disabled, CPU halt; other clock sources,
ADC, timers, and serial interface disabled
IOP;VSYS
VSYS operating supply current
fFRCLK = fHCLK = fACLK = ROSC 00, PLL
disabled, CPU halt; other clock sources,
ADC, timers, and serial interface disabled
fFRCLK = fHCLK = fACLK = CLKREF, PLL
disabled, CPU halt; other clock sources,
ADC, timers, and serial interface disabled
fFRCLK = fHCLK = fACLK = 10MHz XTAL, PLL
disabled, CPU halt; other clock sources,
ADC, timers, and serial interface disabled
fFRCLK = 4MHz CLKREF, fHCLK = 50MHz, fACLK
= fOUTPLL = 100MHz, CPU halt; other clock
sources, ADC, timers, and serial interface
disabled
IQ;VCCIO
VCCIO quiescent supply current
TYP
3.4
4
5.3
9
2.3
4.5
23.3
0.02
MAX
50
UNIT
MHz
mA
mA
- 56 -
Rev 1.0‒February 25, 2014