English
Language : 

APA075-TQ144I Datasheet, PDF (40/174 Pages) Actel Corporation – Ultra-Fast Local and Long-Line Network
ProASICPLUS Flash Family FPGAs
Table 1-21 • DC Electrical Specifications (VDDP = 2.5 V ±0.2V)
Commercial/Industrial/
Military/MIL-STD-8831, 2
Symbol Parameter
Conditions
Min.
Typ.
Max. Units
VOH
Output High Voltage
High Drive (OB25LPH)
Low Drive (OB25LPL)
VOL
Output Low Voltage
High Drive (OB25LPH)
Low Drive (OB25LPL)
VIH6
Input High Voltage
VIL7
Input Low Voltage
RWEAKPULLUP Weak Pull-up Resistance
(OTB25LPU)
IOH = –6 mA
IOH = –12 mA
IOH = –24 mA
IOH = –3 mA
IOH = –6 mA
IOH = –8 mA
IOL = 8 mA
IOL = 15 mA
IOL = 24 mA
IOL = 4 mA
IOL = 8 mA
IOL = 15 mA
VIN ≥ 1.25 V
2.1
2.0
1.7
V
2.1
1.9
1.7
0.2
0.4
0.7
V
0.2
0.4
0.7
1.7
VDDP + 0.3 V
–0.3
0.7
V
6
56
kΩ
HYST
Input Hysteresis Schmitt
See Table 1-4 on page 1-9
0.3
0.35
0.45
V
IIN
Input Current
with pull up (VIN = GND)
–240
– 20
µA
without pull up (VIN = GND or VDD)
–10
10
µA
IDDQ
Quiescent Supply Current
VIN = GND4 or VDD
(standby)
Commercial
Std.
5.0
15
mA
–F3
5.0
25
mA
IDDQ
Quiescent Supply Current
VIN = GND4 or VDD
(standby)
Industrial
Std.
5.0
20
mA
IDDQ
Quiescent Supply Current
VIN = GND4 or VDD
(standby)
Military/MIL-STD-883
Std.
5.0
25
mA
IOZ
Tristate Output Leakage Current VOH = GND or VDD
Std. –10
–F3, 5 –10
10
µA
100
µA
Notes:
1. All process conditions. Commercial/Industrial: Junction Temperature: –40 to +110°C.
2. All process conditions. Military: Junction Temperature: –55 to +150°C.
3. All –F parts are available only as commercial.
4. No pull-up resistor.
5. This will not exceed 2 mA total per device.
6. During transitions, the input signal may overshoot to VDDP +1.0V for a limited time of no larger than 10% of the duty cycle.
7. During transitions, the input signal may undershoot to -1.0V for a limited time of no larger than 10% of the duty cycle.
1-36
v5.2