Z90365 Datasheet, PDF (5/8 Pages) Zilog, Inc. – Digital Television Controller
Zilog
V1, V2, V3 (R, G, B) ANALOG OUTPUT (PRELIMINARY)
TA = 0°C to 70°C
data = 00
data = 01
data = 10
data = 11
Output Voltage (30 kΩ load)
VCC = 4.75
0.00v .. 0.65v
1.70v ± 0.20v
2.80v ± 0.25v
3.90v ± 0.3v
5.00V
0.00v .. 0.70v
1.80v ± 0.20v
2.90v ± 0.25v
4.0v ± 0.30v
5.25V
0.00v .. 0.75v
1.90v ± 0.20v
3.00v ± 0.25v
4.10v ± 0.30v
Z90365
Digital Television Controller
1
Settling Time
70% of DC level, 10pF load
‹ 50 ns
22 pF
47 pF
XTAL1
68 KΩ
XTAL2
Z90365
Figure 3. 32 kHz Oscillator Recommended Circuit
Z90365
510 Ω
47 µF
0.1 µF
Figure 4. Recommended Low Pass Filter Circuit
CP97TEL2800
PRELIMINARY