AT-128128H1FI-00H Datasheet, PDF (8/16 Pages) ZETTLER Electronics – SPECIFICATIONS FOR LCD MODULE
7 Software setting
Please must follow the blow setting. Otherwise the temp consumption circuit can’t work very
well. These setting are related to temp consumption circuit, especially in Power control.
Power control
R/W RS DB15 DB14 DB13 DB12 DB11 DB10 DB9 DB8 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
0 1 * * * BS2 BS1 BS0 BT1 BT0 * * DC1 DC0 AP1 AP0 SLP STB
010000011100110100
1/10 BIAS
7-TIMES
4-DIVIDED SMALL
Contrast control
R/W RS DB15 DB14 DB13 DB12 DB11 DB10 DB9 DB8 DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
0 1 * * * * * * * * * * CT5 CT4 CT3 CT2 CT1 CT0
010000000000101000
28 (HEX) , 40 (DEC)
Date : 2003/2/21
AMPIRE CO., LTD.