English
Language : 

AT-128128H1FI-00H Datasheet, PDF (14/16 Pages) ZETTLER Electronics – SPECIFICATIONS FOR LCD MODULE
10.6 RELIABILITY
Test Item
Test Conditions
Extend Temp. type
Note
High Temperature Operation
Low Temperature Operation
High Temperature Storage
Low Temperature Storage
Thermal Shock Test
75±3°C , t=96 hrs
-20±3°C , t=96 hrs
80±3°C , t=96 hrs
1,2
-30±3°C , t=96 hrs
1,2
-30°C ~ 25°C ~ 80°C
30 m in. 5 min. 30 min. ( 1 cycle ) 1,2
Total 5 cycle
Humidity Test
40 °C, Humidity 90%, 96 hrs
1,2
Sweep frequency : 10 ~ 55 ~ 10 Hz/1min
Vibration Test (Packing)
Amplitude : 0.75mm
Test direction : X.Y.Z/3 axis
2
Duration : 30min/each axis
Note 1 : Condensation of water is not permitted on the module.
Note 2 : The module should be inspected after 1 hour storage in normal conditions
(15-35°C , 45-65%RH).
Definitions of life end point :
z Current drain should be smaller than the specific value.
z Function of the module should be maintained.
z Appearance and display quality should not have degraded noticeably.
z Contrast ratio should be greater than 50% of the initial value.
Date : 2003/2/21
AMPIRE CO., LTD.
14