English
Language : 

AC-204AYILY-70-A Datasheet, PDF (15/17 Pages) ZETTLER Electronics – SPECIFICATIONS FOR LCD MODULE
12.6 RELIABILITY
Test Item
Test Conditions
Normal Temp. type
Note
High Temperature Operation
Low Temperature Operation
High Temperature Storage
Low Temperature Storage
Thermal Shock Test
50±3°C , t=96 hrs
0±3°C , t=96 hrs
70±3°C , t=96 hrs
-20±3°C , t=96 hrs
-20°C ~ 25°C ~ 70°C
30 min. 5 min. 30 min.
Total 5 cycle
1,2
1,2
( 1 cycle )1,2
Humidity Test
40 °C, Humidity 90%, 96 hrs
1,2
Sweep frequency : 10 ~ 55 ~ 10 Hz/1min
Vibration Test (Packing)
Amplitude : 0.75mm
Test direction : X.Y.Z/3 axis
2
Duration : 30min/each axis
Note 1 : Condensation of water is not permitted on the module.
Note 2 : The module should be inspected after 1 hour storage in normal conditions
(15-35°C , 45-65%RH).
Definitions of life end point :
l Current drain should be smaller than the specific value.
l Function of the module should be maintained.
l Appearance and display quality should not have degraded noticeably.
l Contrast ratio should be greater than 50% of the initial value.
2005/8/25
AMPIRE CO., LTD.
15