English
Language : 

ZL50074 Datasheet, PDF (31/61 Pages) Zarlink Semiconductor Inc – 32 K x 32 K Channel TDM Switch with 128 Input and 128 Output Streams
ZL50074
Data Sheet
The address range for a particular stream is given by adding the group start address, as indicated in Table 12, to
the appropriate stream offset range, as indicated in Table 13. For example, the Connection Memory address range
for SToB12 operating at 32 Mbps is 00C800-00CFFF; the Connection Memory address range for SToC4 operating
at 8 Mbps is 004400-0045FF.
Each output channel timeslot occupies a range of 4 addresses in the Connection Memories. The timeslot address
offset is illustrated in Table 14. It shows the maximum number of timeslots that a stream can have, but the actual
number of timeslots available depends on the output data rates, as illustrated in Table 1 and Table 13.
SToAn
Timeslot
SToBn SToCn
SToDn
Address
Offset hex
0
0
0
0
000
1
1
1
1
004
2
2
2
2
008
-
-
-
-
-
126
126
126
126
1F8
127
127
127
127
1FC
128
128
128
128
200
129
129
129
129
204
-
-
-
-
-
254
254
254
254
3F8
255
255
255
255
3FC
256
256
400
257
257
404
-
-
-
-
-
510
510
7F8
511
511
7FC
512
800
513
804
-
-
1021
FF4
1022
FF8
1023
FFC
Table 14 - Connection Memory Timeslot Address Offset Range
31