ZL50019 Datasheet, PDF (21/115 Pages) Zarlink Semiconductor Inc – Enhanced 2 K Digital Switch with Stratum 4E DPLL
ZL50019
Data Sheet
unused ST-BUS/GCI-Bus channel (high impedance) are driven high. Refer to Figure 18 on page 32 for a
diagrammatical explanation.
5.2 Input Clock (CKi) and Input Frame Pulse (FPi) Timing
The input clock for the ZL50019 can be arranged in one of three different ways. These different ways will be
explained further in Section 12.1 to Section 12.3 on page 37. Depending on the mode of operation, the input clock,
CKi, will be based on the highest data rate of either the input or both the input and output data rates. The user has
to program the CKIN1 - 0 (bits 6 - 5) in the Control Register (CR) to indicate the width of the input frame pulse and
the frequency of the input clock supplied to the device.
In Master mode and Divided Slave mode, the input clock, CKi, must be at least twice the highest input or output
data rate. For example, if the highest input data rate is 4.096 Mbps and the highest output data rate is 8.192 Mbps,
the input clock, CKi, must be 16.384 MHz, which is twice the highest overall data rate. The only exception to this is
for 16.384 Mbps input or output data. In this case, the input clock, CKi, is equal to the data rate. The input frame
pulse, FPi, must always follow CKi.
In Master mode, CKo2 and FPo2 can be programmed to be used as CKi and FPi by setting CKi_LP (bit 10) in the
Control Register (CR). This will internally loop back the CKo2 and FPo2 timing. When this bit is set, CKi and FPi
must be tied low or high externally.
Highest Input or Output
Data Rate
CKIN 1-0 Bits
Input Clock Rate (CKi) Input Frame Pulse (FPi)
16.384 Mbps or 8.192 Mbps
00
16.384 MHz
8 kHz (61 ns wide pulse)
4.096 Mbps
01
8.192 MHz
8 kHz (122 ns wide pulse)
2.048 Mbps
10
4.096 MHz
8 kHz (244 ns wide pulse)
Table 1 - CKi and FPi Configurations for Master and Divided Slave Modes
In Multiplied Slave mode, the input clock, CKi, must be at least twice the highest input data rate, regardless of the
output data rate. Following the example above, if the highest input data rate is 4.096 Mbps, the input clock, CKi,
must be 8.192 MHz, regardless of the output data rate. The only exception to this is for 16.384 Mbps input data. In
this case, the input clock, CKi, is equal to the data rate. The input frame pulse, FPi, must always follow CKi.
Highest Input Data Rate
CKIN 1-0 Bits
Input Clock Rate (CKi) Input Frame Pulse (FPi)
16.384 Mbps or 8.192 Mbps
00
16.384 MHz
8 kHz (61 ns wide pulse)
4.096 Mbps
01
8.192 MHz
8 kHz (122 ns wide pulse)
2.048 Mbps
10
4.096 MHz
8 kHz (244 ns wide pulse)
Table 2 - CKi and FPi Configurations for Multiplied Slave Mode
The ZL50019 accepts positive and negative ST-BUS/GCI-Bus input clock and input frame pulse formats via the
programming of CKINP (bit 8) and FPINP (bit 7) in the Control Register (CR). By default, the device accepts the
negative input clock format and ST-BUS format frame pulses. However, the switch can also accept a positive-going
clock format by programming CKINP (bit 8) in the Control Register (CR). A GCI-Bus format frame pulse can be
used by programming FPINPOS (bit 9) and FPINP (bit 7) in the Control Register (CR).
21
Zarlink Semiconductor Inc.