CCB200 Datasheet, PDF (7/10 Pages) XP Power Limited – Very Long Capacitor Lifetime
xppower.com
Thermal Considerations
In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be
exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of any direct air flow). See
Mechanical Details for component locations.
Component
T1
L3
C64
C53
Temperature Measurements (Ambient ≤ 50 ° C)
Max Temperature ° C
120 °C
120 °C
105 °C
105 °C
Service Life
The estimated service life of the CCB200 is determined by the cooling arrangements and load conditions experienced in the end application. Due to
the uncertain nature of the end application this estimated service life is based on the actual measured temperature of a key capacitor within the product
when installed in the end application.
The graph below expresses the estimated lifetime for a given component temperature and assumes continuous operation at this temperature.
Estimated Service Life vs Component Temperature
Figure 9
185000
165000
145000
125000
105000
85000
65000
45000
25000
5000
105
95
85
75
65
55
C64 Temperature (°C)
7