English
Language : 

CCB200 Datasheet, PDF (6/10 Pages) XP Power Limited – Very Long Capacitor Lifetime
Environmental
Characteristic
Operating Temperature
Storage Temperature
Cooling
Humidity
Operating Altitude
Shock
Vibration
xppower.com
Minimum
-20
-40
5
Typical
Maximum
+85
+85
95
5000
Units
°C
°C
%RH
m
Notes & Conditions
See fig.8 & Thermal Considerations, p.7.
Convection cooled.
See fig.8 & Thermal Considerations, p.7.
Non-condensing
±3 x 30g shocks in each plane, total 18
shocks. 30g = 11ms (+/-0.5msec), half sine.
Conforms to EN60068-2-27 & EN60068-2-47
Single axis 10 - 500 Hz at 2g sweep and
endurance at resonance in all 3 planes.
Conforms to EN60068-2-6
Derating Curve
Figure 8
200
182
160
150
100
Standby Covered
Convection (-AC)
Covered Convection (-C)
Open Frame Convection
0
-20 -10 0
+50 +70
+85
Ambient Temperature (ºC)