English
Language : 

CCM250 Datasheet, PDF (6/12 Pages) XP Power Limited – 250 W Convection Cooled
Characteristic
Signals
Power Fail
Remote On/Off (Inhibit/Enable)
Standby Supply V2
xppower.com
Notes & Conditions
Uncomitted opto isolated transistor, normally off when AC is good (see fig.9 - 11)
Provides ≥ 5 ms (typically 20-30ms) warning of loss of output from AC failure
Uncommited isolated optocoupler diode, powered diode inhibits the supply (see fig.12-17)
Isolated 5 V/0.5 A supply, always present when AC supplied.
Signals
Power Fail
Figure 9
POWER SUPPLY
8V Max 3 mA
Signal Connector
Pin 2, 4 & 6
CON 1
5 V Standby
2K2
Pin 7 CON 1
Power Fail
Collector
Power Fail
Emitter
Pin 8 CON 1
5 V Standby Rtn
Pin 1, 3 & 5
CON 1
Transistor On (<0.8 V): Input & Output Not OK
Transistor Off (>4.5 V): Input & Output OK
Power Fail
V1
V2
Power Fail
V1
Figure 10
Power Fail signal example
at AC switch off
Figure 11
V1 warning time example at Power Fail signal 230
VAC 250 W load (35 ms)
6