English
Language : 

CCM250 Datasheet, PDF (5/12 Pages) XP Power Limited – 250 W Convection Cooled
XGxexnxexrxaxl xSxpxecifications
Characteristic
Efficiency
Isolation: Input to Output
Input to Ground
Output to Ground
Switching Frequency
Power Density
Mean Time Between Failure
Weight
Minimum
4000
1500
500
Typical
93
30-500 / 25.6 / 51.2
365
1.7 (780)
Maximum
95
6.9
xppower.com
Units
%
VAC
VAC
VAC
kHz
W/in3
kHrs
lb (g)
Notes & Conditions
Full load (see fig.7 & 8)
PFC / Boost / Main Converter.
MIL-HDBK-217F, Notice 2
+25 °C GB
Efficiency Versus Load
100%
90%
80%
70%
60%
50%
40%
10
20
30
40
50
60
70
80
90 100
230Vac input
Load (%)
Figure 7
CCM250PS12
100%
90%
80%
70%
60%
50%
40%
10
20
30
40
50
60
70
80
90
100
Load (%)
230VAC input
Figure 8
CCM250PS24
Power Loss
Waste heat creates a big headache for system designers. The industry leading efficiency achieved by the CCM250 is 5-10% above existing topologies
used in this power area. This can result in a 70% reduction in generated heat as shown below and enables the overall system to run much cooler and
more reliably.
Example 1
Efficiency
Generated Heat
% Losses
Conventional Products
85 %
44.1 W
100 %
CCM250
95 %
13.1 W
30 %
Example 2
Efficiency
Generated Heat
% Losses
Conventional Products
90 %
27.8 W
100 %
CCM250
95 %
13.1 W
47 %
5