English
Language : 

HDS1500 Datasheet, PDF (4/6 Pages) XP Power Limited – AC-DC Power Supplies
HDS1500 Series
AC-DC Power Supplies
Signals & Controls
LED Status
Solid (Green)
Solid (Orange)
Slow Blink (Green)
Fast Blink (Red)
Solid (Red)
Slow Blink (Red)
Intermittent Blink (Red)
Short & Long Blink (Red)
Remote Enable
Output Status
DC Output OK
DC Output OK in remote control mode
Output Not Enabled
Over Voltage
Over Loaded
Over Temperature
Fan Fail
AUX Standby Failure
5 V SB
2KΩ EN+
SW
5V
OFF Power OFF
ON Power ON
EN-
GND
(A) Using internal 5 V standby
5 V SB
2KΩ EN+
L Power OFF
5V
H Power ON
EN-
GND
L/H
GND
(B) Using external transistor
5 V SB
OFF Power OFF
ON Power ON
2KΩ EN+
SW
5V
5V
EN-
GND
(C) Using external voltage source
EMC: Emissions
Phenomenon
Conducted
Radiated
Harmonic Currents
Voltage Flicker
EMC: Immunity
Phenomenon
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted
Magnetic Field
Dips and Interruptions
Safety Approvals
Safety Agency
UL
CSA
TUV
Standard
EN55022
EN55022
EN61000-3-2
EN61000-3-3
Test Level
Class B
Class B
Class A
Notes & Conditions
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN55024
Test Level
2/3
3
3
Installation class 3
3
3
DIP: 30% 500 ms
INT: >95% 10 ms
INT: >95% 5000 ms
Criteria
A
A
A
A
A
A
A/B
A
B
Notes & Conditions
±4 kV contact / ±8 kV air discharge
High Line/Low Line
Safety Standard
UL60950-1
C22.2 No.60950-1
EN60950-1
Notes & Conditions
www.xppower.com
4