English
Language : 

GCS265 Datasheet, PDF (4/8 Pages) XP Power Limited – AC-DC Power Supplies
GCS265 Series
AC-DC Power Supplies
Signals & Controls
Characteristic
Power Fail (AC-OK)
Standby Supply
Remote Sense
Remote On/Off
Power Fail (AC-OK)
Figure 6
POWER SUPPLY
Max 12 V 20 mA
5 V Standby
Pin 7 & 8
330R
AC OK Collector
Pin 6
Inhibit
Enable
Notes & Conditions
Open collector pin 6 referenced to -ve sense pin 2 of J4.
Provides ≥2 ms warning of loss of output from AC failure.
5 VDC/3.0 A Isolated supply present when AC applied.
Compensates for 0.5 V total voltage drop
The inhibit lo (pin 4), should be pulled below 0.4 V to switch V1 & Vfan off. Open circuit or >4 V to
switch on (see fig. 7)
With the inhibit lo (pin 4) pulled low as detailed above, connecting inhibit hi (pin 5) to inhibit lo (pin 4)
will enable V1 & V fan output. (see fig. 8)
Remote On/Off (Inhibit)
Figure 7
Remote On/Off (Enable)
Figure 8
Inhibit Lo
Pin 4
POWER SUPPLY
Inhibit Hi
Pin 5
Inhibit Lo
Pin 4
POWER SUPPLY
AC OK Emitter
Pin 2
Transistor On (<0.8 V): AC NOT OK
Transistor Off (>4.5 V): AC OK
0V
0V
J4 Logic Connector
5 V Standby
Return Pin 9 & 10
Signals Connector
Signals Connector
Environmental
Characteristic
Operating Temperature
Storage Temperature
Cooling
Humidity
Operating Altitude
Shock
Vibration
Minimum
-40
-40
7
5
Typical
Thermal Derating Curve
Figure 9
100
Maximum
+70
+85
95
TBA
Units
°C
°C
CFM
%RH
m
Notes & Conditions
See derating curve, fig. 9
Forced Cooled >180 W
Non-condensing
±3 x 30g shocks in each plane, total 18 shocks. 30g =
11ms (+/-0.5msec), half sine. Conforms to EN60068-2-27
& EN60068-2-47
Single axis 10 - 500 Hz at 2g sweep and endurance at
resonance in all 3 planes. Conforms to EN60068-2-6
50
0
-40 -20 0
+50
+70
Ambient Temperature (ºC)
www.xppower.com