English
Language : 

AMM Datasheet, PDF (4/4 Pages) XP Power Limited – Worldwide Medical Approvals
Models and Ratings
AMM150
Output
Power
132 W
144 W
150 W
150 W
150 W
150 W
Output
Voltage
12 V
15 V
19 V
24 V
27 V
48 V
Output
Current
11.00 A
9.60 A
7.90 A
6.25 A
5.56 A
3.13 A
Total
Regulation(2)
5%
5%
5%
5%
5%
5%
Model
Number(4,5)
AMM150PS12
AMM150PS15
AMM150PS19(6)
AMM150PS24(3,6)
AMM150PS27(3,6)
AMM150PS48(3,6)
Notes
1. Ripple and noise measured at 20 MHz bandwidth with a 10 µF tantalum and 0.1 µF ceramic capacitor connected at the measurement point.
2. Total regulation includes set accuracy, line and load regulation.
3. For optional barrel jack connector, add suffix ‘ B1’ to the model number e.g. AMM150PS24B1 (not available on 12 V models)
4. For optional AC cable restraint on the Class I Version, add suffix ‘ A’ to the model number e.g. AMM150PS24A or AMM150PS24B1A. AC mains lead must be
Interpower Corporation, part number: 70006020300. Optional AC cable restraint is not available on the Class II Version.
5. For Class II Versions, and ‘ C2’ to model number, eg. AMM150PS24C2.
6. Energy Star Level V.
Mechanical Details
1.96
(49.7)
Power On Indicator
13
Cable length approx 48” (1219 mm)
24
Rubber foot
(4 places.)
8.17
(207.6)
1
3
2
4
Pin
Function
1
Return
2
Output+
3
Return
4
Output+
3.23 (82.0)
Optional Barrel Jack Connector
0.433 (11.0)
0.217
(5.5)
0.083 (2.1) 0.413
(10.5)
AC Input
Notes
IEC 320/C14 Inlet - For Class I Version
IEC 320/C18 Inlet - For Class II Version
1. Dimensions shown in inches (mm).
Tolerance is 0.02 (0.5) maximum, except output cable length.
2. Weight: 2.16 lbs (980 g).
3. Output connector is 4 Pin DC Power Plug, locking type.
For mating half, use KYCON KPJX-4S-S or equivalent.
4. For Class I versions shell is connected to ground. For Class II Versions shell is
capacitively coupled to input.
5. For European mains lead order part: EU-MAINS-IEC
6. For UK mains lead order part: UK-MAINS-IEC
7. For US mains lead order part: US-MAINS-IEC
8. Mains lead length is 78“ (2000 mm) approx
31-Jan-12