AMM Datasheet, PDF (1/4 Pages) XP Power Limited – Worldwide Medical Approvals | |||
|
90 150 Watts
AMM Series
xppower.com
⢠CEC2008 & EISA2007 Compliant
⢠Worldwide Medical Approvals
⢠Class I and Class II Versions
⢠High Power Density
⢠High Efficiency
⢠Operating Temperature up to +60 °C
⢠3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
⢠90 W: 80-264 VAC, derate output power
10% <90 VAC & 15% <85 VAC,
120/150 W: 80-264 VAC, derate output
power 15% <90 VAC & 20% <85 VAC
⢠47-63 Hz
Input Current
⢠90 W: 1.2 A at 115 VAC, 0.6 A at 230 VAC
120 W: 1.6 A at 115 VAC, 0.8 A at 230 VAC
150 W: 2 A at 115 VAC, 1.0 A at 230 VAC
Inrush Current
Power Factor
Earth Leakage Current
(Class I Versions)
Input Protection
No Load Input Power
⢠60 A max at 115 VAC, 120 A max at
230 VAC, cold start +25 °C
⢠0.98 typical
⢠90 µA max at 115 VAC/60 Hz,
150 µA max at 230 VAC/50 Hz
⢠90 W: Internal T2.5 A/250 V fuse in line
and neutral lines,
120 W: Internal T3.15 A/250 V fuse in line
and neutral lines,
150 W: Internal T4 A/250 V fuse in line and
neutral lines
⢠<0.5 W
Output
Output Voltage
⢠See tables
Output Voltage Trim ⢠Not user-adjustable
Initial Set Accuracy ⢠±2%, set at 60% load
Minimum Load
⢠No minimum load required
Start Up Delay
⢠90/120 W: 2 s max at 115 VAC,
150 W: 3 s max at 115 VAC
Start Up Rise Time
⢠<80 ms at 115 VAC
Hold Up Time
⢠15 ms minimum at full load & 115 VAC
Line Regulation
⢠0.5% maximum
Load Regulation
⢠See tables
Transient Response
⢠4% max. deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise
⢠2% max pk-pk (see note 1)
Overvoltage Protection ⢠110-140% Vnom, recycle input to reset
Overtemperature
Protection
⢠90/150 W: Unit shuts down, auto recovery
120 W: Unit shuts down, recycle input
to reset
Overload Protection ⢠110-180%, auto recovery
Short Circuit Protection ⢠Trip and restart (Hiccup mode)
Temperature
Coefficient
⢠0.04%/°C
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
⢠85% typical
⢠4000 VAC Input to Output
1500 VAC Input to Ground (Class I only)
500 VAC Output to Ground (Class I only)
⢠50-110 kHz variable
⢠90 W: 3.4 W/In3, 120 W: 3.7 W/In3
150 W: 2.9 W/In3
⢠150 kHrs typical to MIL-HDBK-217F
at 25 ÅC, GB
Environmental
Operating Temperature ⢠0 °C to +60 °C, derate linearly from 100%
power at +40 °C to 50% power at +60 °C
Cooling
⢠Convection-cooled
Operating Humidity ⢠5-95% RH, non-condensing
Storage Temperature ⢠-40 ÅC to +85 ÅC
Operating Altitude
⢠3000 m
Shock
⢠30 g, 10 ms on 3 axes
Vibration
⢠5-100 Hz, 2.31 m/s2, 20 mins, 3 axes
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
Safety Approvals
⢠EN55011/FCC/VCCI, Class B conducted
EN55011/FCC/VCCI, Class B radiated
⢠EN61000-3-2, Class A
⢠EN61000-3-3
⢠EN61000-4-2, level 3 Perf Criteria A
⢠EN61000-4-3, level 2 Perf Criteria A
⢠EN61000-4-4, level 3 Perf Criteria A
⢠EN61000-4-5, level 3 Perf Criteria A
⢠EN61000-4-6, 3 V Perf Criteria A
⢠EN61000-4-8, 3 A/m Perf Criteria A
⢠EN61000-4-11
90/120 W: 70% 10 ms, 40% 100 ms,
<5% 5000 ms, Perf Criteria A, B, B (Perf
Criteria A, A, B with 70% load)
150 W: >95% 10 ms, 60% 100 ms,
<30% 500 ms, Perf Criteria A, B, B
⢠EN60601-1, UL60601-1,
CSA22.2 No. 601-1 per cUL
|
▷ |