English
Language : 

HPU1K5 Datasheet, PDF (3/4 Pages) XP Power Limited – 1500 Watts HPU1K5 Series
Signals
HPU1K5
AC OK/Power Fail
AC OK is an isolated signal providing a minimum of 3 ms warning of loss of
output regulation. The signal is fully isolated and the collector and emitter must
be connected externally.
Maximum sink current 2 mA, maximum voltage 20 V.
DC OK
DC OK is an isolated signal providing warning that the output voltage has fallen
below 90% of nominal. The signal is fully isolated and the collector and emitter
must be connected externally.
Maximum sink current 2 mA, maximum voltage 20 V.
POWER SUPPLY
J3 Connector
5 V Standby
Pin 20
3300R
AC OK Collector
Pin13
AC OK Emitter
Pin 17
Transistor On (<0.8 V): AC OK
Transistor Off (>4.5 V): AC NOT OK
5 V Standby
Return Pin 19
POWER SUPPLY
J3 Connector
5 V Standby
Pin 20
3300R
DC OK Collector
Pin 15
DC OK Emitter
Pin 17
Transistor On (<0.8 V): DC OK
Transistor Off (>4.5 V): DC NOT OK
5 V Standby
Return Pin 19
Inhibit
Inhibit is an isolated control signal which can turn the power supply and fans off
by supplying 2 to 5 mA into the pin.
800R
5 V Standby
Pin 20
2-5 mA
100R
0 V or Floating: Power Supply On
2-5 mA: Power Supply Off
Inhibit
Pin 9
POWER SUPPLY
Inhibit
Return Pin 17
5 V Standby
Return Pin 19
J3 Connector
Fault
Fault is an isolated signal providing warning of either Power Fail or DC fail.
The signal is fully isolated and the collector and emitter must be connected
externally.
Maximum sink current 2 mA, maximum voltage 20 V.
POWER SUPPLY
J3 Connector
5 V Standby
Pin 20
3300R
Fault Collector
Pin 11
Fault Emitter
Pin 17
Transistor On (<0.8 V): FAULT
Transistor Off (>4.5 V): OK
5 V Standby
Return Pin 19
V Program
V Program allows remote voltage adjustment within the range ±10%
POWER SUPPLY
Current Share
Connecting pins 5 or 6 and 3 or 4 of like voltage units (8 maximum) will force the
current to share between the outputs. Units share current within 10% of each
other at full load. Derate output to 90% of total combined load.
J3 Connector
V Trim
Pin 7
- Sense
Pin 3 & 4
V Program V Output
0V
-10%
5V
+10%
Open
Factory
Circuit Set Voltage
PSU 1
PSU 2
Pin
5 or 6
Pin
Pin
3 or 4 5 or 6
Pin
3 or 4
PSU 8
Pin
5 or 6
Pin