English
Language : 

DDC15 Datasheet, PDF (3/4 Pages) XP Power Limited – DDC15 Series
DDC15 Series
EMC: Emissions
Phenomenon
Conducted
Radiated
Standard
EN55022
EN55022
DC-DC Power Supplies
Test Level
Class B
Class B
Criteria
Notes & Conditions
EMC: Immunity
Phenomenon
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted
Magnetic Fields
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Test Level
6 kV
8 kV
10 V/m
2
1
10 V
4
Criteria
A
A
A
A
A
A
Notes & Conditions
Contact
Air Discharge
Safety Approvals
Safety Agency
UL
TUV
CB
Safety Standard
UL508
EN60950-1 +A2:2013
IEC60950-1 +A2:2013
Notes & Conditions
Industrial Control Equipment
Information Technology
Information Technology
Application Notes
Derating Curves
120
100
80
<9.5 V input
60
40
20
-40
-20
>28.0 V input
0
20
40
60
Ambient Temperature (°C)
100
80
Safe Operating Area
0
80
9
28
36
Input Voltage (V)
3
www.xppower.com