English
Language : 

DDC15 Datasheet, PDF (2/4 Pages) XP Power Limited – DDC15 Series
DDC15 Series
DC-DC Power Supplies
Input
Characteristic
Input Voltage Range
Input Current
Inrush Current
Input Filter
Undervoltage Lockout
Input Surge
Input Protection
Minimum
9
Typical
Pi type
On at >8.5 V
T3.0A/63 VDC Internal Fuse
Maximum
36
95
40
Units
VDC
A
Notes & Conditions
See Models and Ratings table
at 36 V
VDC
No Damage
Output
Characteristic
Output Voltage
Output Voltage Trim
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Line Regulation
Load Regulation
Transient Response
Ripple & Noise
Short Circuit Protection
Overload Protection
Overvoltage Protection
Temperature Coefficient
Minimum
5
0
0
110
115
Typical
50
11
Maximum
24
±1
±1
±1.5, ±1
4
100
165
135
0.03
Units
V
%
%
A
ms
ms
%
%
% deviation
mV pk-pk
%
%
%/ ˚C
Notes & Conditions
See Models and Ratings table
See Models and Ratings table
No minimum load required
3V3 model, other models
Recovery to within 1% in <1 ms for a 50% load change
at 0.25 A/µs rate
20 MHz bandwidth
Trip & Restart (hiccup mode), auto recovery
Trip & Restart (hiccup mode)
Of nominal output voltage
General
Characteristic
Efficiency
Isolation
Switching Frequency
Power Density
Mean Time Between Failure
Weight
DC ON Indicator
DC Low Indicator
Minimum
1500
150
990
90
70
Typical
82
0.143 (65.0)
Maximum
300
2.7
90
Units
%
VDC
kHz
W/in3
kHrs
lb (g)
%
%
Notes & Conditions
See Models and Ratings table
Variable
MIL-HDBK-217F, +25 °C GB
Of nominal voltage. Green LED
Of nominal voltage. Red LED
Environmental
Characteristic
Operating Temperature
Storage Temperature
Humidity
Operating Altitude
Cooling
Shock
Vibration
Minimum
Typical
Maximum
Units
Notes & Conditions
-40
+70
°C
See derating curve
-55
+85
°C
5
95
%RH
Non-condensing
4850
m
Natural convection
±3 shocks in each plane, total 36 shocks of 15 g : 11 ms halfsine. Conforms to EN60068-2-27
10-500 Hz at 2 g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6
www.xppower.com
2